Below is a list of common 
problems and the probable causes:

Pump will not start

1. No power to the motor. 

Check for blown fuse 
or tripped circuit.

2. Hand-off-auto switch may be

in the off position.

3. Control circuit transformer

fuse may be blown.

4. Overload relay on starter may

be tripped. Push to reset.

Pump will not start and 
overload heaters trip

1. Turn off power and check

motor leads with megger or
ohmmeter for possible ground.

2. Check resistance of motor

windings. All 3 phases 
should show close to the 
same reading.

3. If no grounds exist and the

motor windings check O.K.,
remove pump from sump 
0and check for clogged or
blocked impeller.

Pump operates with selector
switch in hand position but will
not operate in auto position

1. This indicates trouble in the

float level control or the 
alternator relay.

2. To check for defective float

control put selector switch in
auto position and turn off main
power. Put a jumper wire on
terminal strip. Turn on power
and if pump starts, trouble is in
float control. Replace control.

Pump
Troubleshooting

Pump runs but will not shut off

1. Pump may be air locked. Turn

pump off and let set for 
several minutes then restart.

2. Lower float control may be

hung-up in the closed position.
Check in sump to be sure 
control is free.

3. Selector switch may be in the

Hand position.

Pump does not deliver proper
capacity

1. Discharge gate valve may 

be partially closed or 
partially clogged.

2. Check valve may be partially

clogged. Raise level up and
down to clear.

3. Pump may be running in

wrong direction. Low speed
pumps can operate in reverse

direction without much noise
or vibration.

4. Discharge head may be too

high. Check total head with
gauge when pump is 
operating. Total head is 
discharge gauge pressure 
converted to feet plus vertical
height from water level in
sump to center line of pressure
gauge installed in discharge
line. Gauge should be installed
on pump side of all valves.
Multiply gauge pressure in
pounds by 2.31 to get head 
in feet.

5. If pump has been in service for

some time and capacity falls
off, remove pump and check
for wear or clogged impeller.

;;

;

;

;

;

;

;

;;;;

;;

;

;;

;;

;

;

;

;

;

;

;

;

;

;

;

;

;

;;

;;;

;;;

;

;;

;

;

;

;

;

;;

;

;

;

;

28

24

27

26

25

19

21

20

18

17

29 15 16

4

5

7

8

23

22

9

10

12

13

14

3

2

1

11

(Not Shown)

Summary of Contents for S4S

Page 1: ...E To the installer Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system Submersible Sewage Pump S4S Pump Installation and Service Manual ...

Page 2: ...anel Sump Level Control Sump level is controlled by HYDROMATIC 3900 mercury switch level controls The 3900 level controls is a metal case mercury switch sealed in a solid polyurethane float The float is held in position by a weight attached to the power cord above the float The cord supports the float and is adjusted for height from the surface Typical duplex systems use three Floats the lowest fl...

Page 3: ... loose with small bar or screw driver in edge of vanes The impeller should turn freely Clean all trash and sticks from sump and connect pump to piping A check valve must be installed on each pump A gate or plug valve in each pump discharge line is also recommended This valve should be installed on the discharge side of the check valve so if necessary to service the check valve the line pressure ca...

Page 4: ...stallation All wires should be checked for grounds with an ohmmeter or Megger after the connections are made This is important as one grounded wire can cause considerable trouble IMPORTANT If equipment is not properly wired and protected as recommended the motor guarantee is void NUMBER OF CONDUCTORS REQUIRED BETWEEN CONTROL PANEL AND NEMA 4 JUNCTION BOX System Number of Number of Number of Type C...

Page 5: ...rs it is recommended that a lightning arrestor be installed at the control panel Complete data on lightning arrestors and cost is available from the factory Lightning arrestors are good insurance against damage to an expensive motor Servicing Instructions IMPORTANT Read all instructions before replacing any parts WARNING Before handling these pumps and controls always disconnect the power first Do...

Page 6: ...TIC special submersible oil Fill chamber until oil covers top of windings Leave air space in top for expansion Use permatex on plug threads Replacing Seals And Bearings 1 Drain all oil from motor chamber as described 2 Remove bolts that hold motor housing to pump housing Remove screws holding seal plate to motor housing 3 Lift rotating assembly rotor shaft and impeller from pump case and place hor...

Page 7: ...in float control Replace control Pump Troubleshooting Pump runs but will not shut off 1 Pump may be air locked Turn pump off and let set for several minutes then restart 2 Lower float control may be hung up in the closed position Check in sump to be sure control is free 3 Selector switch may be in the Hand position Pump does not deliver proper capacity 1 Discharge gate valve may be partially close...

Page 8: ...HP 3ø 575V R 1 8 Ref Part Part No No Description Qty 14713 003 1 Stator 71 2HP 3ø 230 460V R 1 14713 203 1 Stator 71 2HP 3ø 200V R 1 14713 603 1 Stator 71 2HP 3ø 575V R 1 27 02577 000 1 Wire Connector As Recq 00282 001 1 Wire Connector 14 16 wire size As Recq 01006 001 1 Wire Connector 10 12 wire size As Recq 28 06461 023 5 Cord Cap Assy 15 Single 10 4 1 06461 024 5 Cord Cap Assy 30 Single 10 4 1 ...

Page 9: ... 28 24 27 26 25 19 21 20 18 17 29 15 16 4 5 7 8 23 22 9 10 12 13 14 3 2 1 11 6 Not Shown 9 S4S ...

Page 10: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Page 11: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Page 12: ...shed to the Buyer shall fail to conform to this contract or to any of the terms of this written warranty Hydromatic Pumps Inc shall replace such nonconforming material at the original point of delivery and shall furnish instruction for its disposition Any transportation charges involved in such disposition shall be for the Buyer s account The Buyer s exclusive and sole remedy on account or in resp...

Reviews: