Hydromatic S4S Installation And Service Manual Download Page 12

© 1999 Hydromatic

®

,  Ashland, Ohio.  All Rights Reserved.

Item# E-03-321  5M  1/01

– Your Authorized Local Distributor –

1840 Baney Road  Ashland, Ohio 44805

Tel: 419-289-3042  Fax: 419-281-4087

www.hydromatic.com   ISO 9001 Certified

Part#  5625-321-1

WARRANTY

Hydromatic Pumps, Inc. warrants to the original purchaser of each Hydromatic product(s) that any part

thereof which proves to be defective in material or workmanship within one year from date of installation or
18 months from manufacture date, whichever comes first, will be replaced at no charge with a new or 
remanufactured part, F.O.B. factory. Purchaser shall assume all responsibility and expense from removal, 
reinstallation and freight. Any item(s) designated as manufactured by others shall be covered only by the 
express warranty of the manufacturer thereof. This warranty does not apply to damage resulting from
accident, alteration, design, misuse or abuse. The pump must be installed, operated and maintained in 
accordance with the published instructions of the appropriate Installation & Service Manual.

All dual seal non-clogs and 3–5 HP grinders must have seal failure and heat sensors attached and functional

for Warranty to be in effect. If a seal failure should occur, Hydromatic Pumps will cover only the lower seal
and labor thereof. Labor based on Authorized Service Center contract allowance. If the heat sensor is not
attached and functional, Warranty is void. If the seal failure sensor is not attached and functional, Warranty
is void.

If the material furnished to the Buyer shall fail to conform to this contract or to any of the terms of this 

written warranty, Hydromatic Pumps, Inc. shall replace such nonconforming material at the original point
of delivery and shall furnish instruction for its disposition. Any transportation charges involved in such
disposition shall be for the Buyer’s account. The Buyer’s exclusive and sole remedy on account or in respect
of the furnishing of material that does not conform to this contract or to this written warranty, shall be to 
secure replacement thereof as aforesaid. Hydromatic Pumps, Inc. shall not in any event be liable for the cost
of any labor expended on any such material or for any incidental or consequential damages to anyone by
reason of the fact that such material does not conform to this contract or to this written warranty.

ALL IMPLIED WARRANTIES, INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY

AND THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, ARE DISCLAIMED
TO THE SAME EXTENT AS THE EXPRESS WARRANTY CONTAINED HEREIN. Some states do not
allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.

MANUFACTURER EXPRESSLY DISCLAIMS AND EXCLUDES ANY LIABILITY FOR 

CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF ANY EXPRESS OR IMPLIED
WARRANTY ARISING IN CONNECTION WITH THIS PRODUCT, INCLUDING WITHOUT
LIMITATION, WHETHER IN TORT, NEGLIGENCE, STRICT LIABILITY CONTRACT OR 
OTHERWISE. Some States do not allow the exclusion or limitation of incidental or consequential damages,
so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and
you may also have other rights which vary from State to State.

Summary of Contents for S4S

Page 1: ...E To the installer Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system Submersible Sewage Pump S4S Pump Installation and Service Manual ...

Page 2: ...anel Sump Level Control Sump level is controlled by HYDROMATIC 3900 mercury switch level controls The 3900 level controls is a metal case mercury switch sealed in a solid polyurethane float The float is held in position by a weight attached to the power cord above the float The cord supports the float and is adjusted for height from the surface Typical duplex systems use three Floats the lowest fl...

Page 3: ... loose with small bar or screw driver in edge of vanes The impeller should turn freely Clean all trash and sticks from sump and connect pump to piping A check valve must be installed on each pump A gate or plug valve in each pump discharge line is also recommended This valve should be installed on the discharge side of the check valve so if necessary to service the check valve the line pressure ca...

Page 4: ...stallation All wires should be checked for grounds with an ohmmeter or Megger after the connections are made This is important as one grounded wire can cause considerable trouble IMPORTANT If equipment is not properly wired and protected as recommended the motor guarantee is void NUMBER OF CONDUCTORS REQUIRED BETWEEN CONTROL PANEL AND NEMA 4 JUNCTION BOX System Number of Number of Number of Type C...

Page 5: ...rs it is recommended that a lightning arrestor be installed at the control panel Complete data on lightning arrestors and cost is available from the factory Lightning arrestors are good insurance against damage to an expensive motor Servicing Instructions IMPORTANT Read all instructions before replacing any parts WARNING Before handling these pumps and controls always disconnect the power first Do...

Page 6: ...TIC special submersible oil Fill chamber until oil covers top of windings Leave air space in top for expansion Use permatex on plug threads Replacing Seals And Bearings 1 Drain all oil from motor chamber as described 2 Remove bolts that hold motor housing to pump housing Remove screws holding seal plate to motor housing 3 Lift rotating assembly rotor shaft and impeller from pump case and place hor...

Page 7: ...in float control Replace control Pump Troubleshooting Pump runs but will not shut off 1 Pump may be air locked Turn pump off and let set for several minutes then restart 2 Lower float control may be hung up in the closed position Check in sump to be sure control is free 3 Selector switch may be in the Hand position Pump does not deliver proper capacity 1 Discharge gate valve may be partially close...

Page 8: ...HP 3ø 575V R 1 8 Ref Part Part No No Description Qty 14713 003 1 Stator 71 2HP 3ø 230 460V R 1 14713 203 1 Stator 71 2HP 3ø 200V R 1 14713 603 1 Stator 71 2HP 3ø 575V R 1 27 02577 000 1 Wire Connector As Recq 00282 001 1 Wire Connector 14 16 wire size As Recq 01006 001 1 Wire Connector 10 12 wire size As Recq 28 06461 023 5 Cord Cap Assy 15 Single 10 4 1 06461 024 5 Cord Cap Assy 30 Single 10 4 1 ...

Page 9: ... 28 24 27 26 25 19 21 20 18 17 29 15 16 4 5 7 8 23 22 9 10 12 13 14 3 2 1 11 6 Not Shown 9 S4S ...

Page 10: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Page 11: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Page 12: ...shed to the Buyer shall fail to conform to this contract or to any of the terms of this written warranty Hydromatic Pumps Inc shall replace such nonconforming material at the original point of delivery and shall furnish instruction for its disposition Any transportation charges involved in such disposition shall be for the Buyer s account The Buyer s exclusive and sole remedy on account or in resp...

Reviews: