Hydromatic JB-1 Installation And Service Manual Download Page 1

Sewage Ejector 
Pump Package

JB-1 System

NOTE! To the installer: Please make sure you provide
this manual to the owner of the pumping equipment or to
the responsible party who maintains the system.

Pump Installation and Service Manual

Summary of Contents for JB-1

Page 1: ... Pump Package JB 1 System NOTE To the installer Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system Pump Installation and Service Manual ...

Page 2: ...tion provided with this product Familiarize yourself with specific details regarding installation and use before attempting the installation 3 Make certain that the ground fault interrupter protected receptacle or control box is within reach of the pump s power cord Use of extension cords that are too long or too light do not deliver sufficient voltage to the pump motor They could also present a s...

Page 3: ...discharge and vent lines Make the necessary measurements and determine the necessary fittings and piping that are required Be sure to observe all local plumbing codes 4 Install the long bolts and nuts Fig 3 Item 3 that are used to fasten the toilet to the tank or subfloor NOTE A standard floor flange is not required The position of the toilet must be determined to allow the longer bolts to be inse...

Page 4: ...he tank to a depth of approximately 4 This can be checked with the tape measure through the opening where toilet is to be installed Plug in the pump The pump will turn on before the water level reaches 4 1 2 CAUTION Unplug the pump before adjusting the switch If the pump does not turn on before 4 1 2 slide the upper rubber stop down the float rod and retest If the pump starts before 3 1 4 slide th...

Page 5: ...5 Figure 1 END VIEW SIDE VIEW Pump Warning Figure 2 ...

Page 6: ...1 16 hole should be drilled in the discharge pipe below the check valve The check valve should be 12 to 18 inches above pump discharge Do not put check valve directly into pump discharge opening NOTE In sumps where the pump is operating daily air locking rarely occurs 4 Pump head may be too high Pump cannot deliver water over 21 0 vertical lift Horizontal distance does not affect pumping except fo...

Page 7: ...eck Valve 1 5 Wax Ring Retail Boxed 1 6 1 2 Foam Gasket Material 1 7 2 Adapt A Flex Pipe Grommet 2 8 Adapt A Flex Pipe Grommet for Cords 1 9 2 x 32 Long Schedule 40 PVC with 2 NPT Male Adapter 1 Figure 3 Installation Hardware Kit Capacity U S G P M Liters Second 0 20 40 60 80 0 1 2 5 HEAD FEET HEAD METERS 10 15 25 20 3 4 8 7 4 10 HP 5 3 4 0 2 SKV40 CURVE ...

Page 8: ...disposition Any transportation charges involved in such disposition shall be for the Buyer s account The Buyer s exclusive and sole remedy on account or in respect of the furnishing of material that does not conform to this contract or to this written warranty shall be to secure replacement thereof as aforesaid Hydromatic shall not in any event be liable for the cost of any labor expended on any s...

Reviews: