Hydrological Services Pty Ltd
Data Logger Model ML1-420
©
Copyright
ML1-420 100-13
Issue 1.00 6 Apr, 2011
Eg
++~~ATH^M/OK/10
Sends +++, then waits 1 second, then send
ATH<CR> then waits up to 10 seconds for an
OK response.
The expected reply and the timeout parameters are optional. If no timeout is specified, then a
default of 60 seconds is used. The timeout may be a one or two digit number.
CLEAR1<CR> Display
the
clear1
sequence
++~~<CR>
Set the clear 1 sequence. Send +++ then wait 1 sec
++//5<CR>
Send +++, no response and wait 5 seconds
After CLEAR1 sequence is performed, CLEAR2 then CLEAR3 and finally CLEAR4
sequence is performed.
4.1.3 Battery Voltage (BV, BVINT)
The MiniLog battery voltage is measured and displayed when the battery voltage command
(
BV
) is executed as well as during a status window command (
ST
)
BV<CR>
Displays the internal and external battery voltages
The battery voltage log interval can be set with the (
BVINT
) command from 1 to 999 mins.
The internal battery, external battery and temperature are logged at this interval. The logged
data can be retrieved using the DUBVI, DUBVE, DUBVT and DUALL commands.
BVINT<CR>
Displays the log interval in mins.
BVINT=015<CR>
Set the battery and temperature log interval to 15 mins.
4.1.4 Temperature (TEMPC)
The MiniLog tempearture is measured and displayed when the temperature command
(
TEMPC
) is executed as well as during a status window command (
ST
)
TEMPC<CR>
Displays the internal temperature in degrees C
The temperature log interval is be set with the (
BVINT
) command above, from 1 to 999
mins. The internal battery, external battery and temperature are logged at this interval. The
logged temperature can be retrieved using the DUTMP, DUBVT and DUALL commands.