Rev A 2003215
Safety Tips
Test GFCI on a monthly basis
To test:
Plug in cord to power source
Observe light is on
Push “test” observe light is off
Press “reset” and verify light is on
TEST
RESET
INDICATOR LIGHT
Preventative Maintenance
Because of the harsh environments in which the HarborHoist G1.5 can be installed, it is very im-
portant to inspect your HarborHoist occasionally to ensure it is at peak performance. (Operating
Properly) On a monthly basis inspect and ensure the following:
GFCI trips and resets properly when the TEST and RESET buttons are pressed (see GFCI Test Pro-
cedure)
All air hoses are firmly attached, clamps are tight, and there are no apparent leaks
All the aluminum components are structurally sound and no heavy corrosion is visible
The hull pads (if equipped) are structurally sound with no severe cracking or damage
All mounting / attachment brackets are secure
If rope mooring is used, inspect the ropes for any issues that may compromise the integrity
Most importantly, run your blower fan at least once a month even during the off season. Press
UP button on the control and let it run about 1 minute to help keep the motor contacts and
brushes clean
If your lift is equipped with an external level sensor, verify it is secured to the lift and no damage
to the sensor or cable is present