INSTALLING THE CONTROLLER

1.  Plug the unit into a standard NEMA 5-15 120V wall outlet. Place the remote sensor 

probe in a well-ven  lated area at plant height.

2.  Plug the CO

2

 device into the power outlet on the front of the controller. Ensure that the 

CO

2

 device has the proper voltage (120V) and will not exceed the maximum amperage 

ra  ng of the unit (15A).

READING CO

2

 LEVELS

1. Allow the unit to warm up for approximately 5 minutes.

2.  Check that the red LED and the yellow LED on the front of the unit (under 

PPM Level

begin to 

fl

 ash. The number of   mes the red LED 

fl

 ashes indicates the thousands of 

PPM. The yellow LED 

fl

 ashes indicate the hundreds of PPM. For example, if the red 

LED 

fl

 ashes one   me and the yellow LED 

fl

 ashes 3   mes, the CO

2

 PPM reading is 

approximately 1300 PPM.

3.  Watch the green LED in the center of the 

PPM Level

 sec  on. It will illuminate when the 

unit is signaling the CO

2

 device to inject.

CHANGING SETTINGS

1.  Turn the 

Setpoint

 adjustment knob to set the desired minimum CO

2

 level. When the 

level drops below this se   ng, the unit will turn on the CO

2

 device. (Typical se   ngs are 

about 1100-1600 PPM for agricultural applica  ons.)

2.  Turn the 

Deadband

 adjustment knob to control the amount over the CO

2

 se   ng 

the CO

2

 should rise before the unit will turn o

  the CO

2

 device. (Typical se   ngs are 

between 50-150 PPM.)

CALIBRATING THE CO

2

 SENSOR

1.  Unplug the controller. Place the unit outside in an uncrowded area, away from people 

or any other CO

2

-producing objects.

2.  Plug the controller into an outside power source or run an extension cord from the unit 

to a power source inside.

3. Let the controller operate normally for about 10 minutes.

4.  Turn the 

Setpoint

 knob fully counter-clockwise and the 

Deadband

 knob fully clockwise. 

When these se   ngs are made on the unit for more than 3 seconds, the controller will 
go into a calibra  on mode and the red LED will come on.

5.  Move away from the controller so that the carbon dioxide in your breath and 

movement mo  on do not a

 ect the reading.

6.  Check for the yellow LED to come on when the calibra  on is complete. A  er 10 

minutes, the unit should read between 300-400 PPM (3-4 yellow LED 

fl

 ashes). The 

calibra  on is complete. Note: If the yellow LED is blinking on/o

  repeatedly, restart the 

calibra  on process from the beginning.

7.  Disconnect the unit from its power source and adjust the se   ngs back to the normal 

se   ngs before bringing it back inside and rea  aching it to the wall and power source. 
Once power is restored, the unit will start working normally again.

TROUBLESHOOTING

How can I tell if the photocell is working? 

There is a built-in 20-second   me delay for the 

photocell to change status. A green 

Day

Ɵ

 me

 LED on the top side right edge of the unit 

will light up when the photocell is in Day  me mode.

The CO

2

 level of the area does not seem to be correct.

 Ensure the unit has good air 

movement around the CO

2

 sensor. Do not breathe near or directly on the CO

2

 sensor, 

which can increase the reading from the CO

2

 you exhale. 

The yellow LED 

fl

 ashes on/o

  a  er calibra  ng.

 The calibra  on procedure did not work, 

possibly due to the remote probe picking up carbon dioxide from your breath or people 
around you. A  empt to calibrate again.

The red and yellow LEDs remain on.

 There is a problem with the CO

2

 sensor. Contact your 

retailer for repair informa  on.

The red and yellow LEDs con  nue to blink on and o

 .

 The unit has experienced a power 

overload condi  on and shut itself down. Reduce the electrical load (maximum of 15 
amps). Unplug unit for 5 seconds to reset the error.

I have no power to my controller unit.

 Check the device that is connected to the unit 

by plugging it directly into a known power supply. If the device works properly and the 
controller unit will s  ll not turn on and no LEDs 
illuminate, contact your retailer for repair and 
warranty issues.

NOTES:

•  Avoid contact with water. Although the APCECO 

is water-resistant, it is not waterproof. Avoid any 
direct contact with water.

INSTRUCTION MANUAL

INSTRUCTION MANUAL

r.

Summary of Contents for autopilot ANALOG CO2 CONTROLLER

Page 1: ...c on device Choose your own CO2 PPM level and deadband se ng and the controller will automa cally maintain the specified CO2 level A series of blinking LED lights shows the generalized readings A built in photocell automa cally deac vates CO2 injec on during the night me A 15 foot remote sensor allows close placement to the plant canopy INSTRUCTION MANUAL ...

Page 2: ...Move away from the controller so that the carbon dioxide in your breath and movement mo on do not affect the reading 6 Check for the yellow LED to come on when the calibra on is complete A er 10 minutes the unit should read between 300 400 PPM 3 4 yellow LED flashes The calibra on is complete Note If the yellow LED is blinking on off repeatedly restart the calibra on process from the beginning 7 Dis...

Page 3: ...eda del Punto de ajuste completamente en el sen do contrario a las agujas del reloj y la rueda de la Banda muerta completamente en el sen do de las agujas del reloj Una vez trascurridos 3 segundos desde que se realicen estos ajustes en la unida el controlador entrará en el modo de calibración y el LED rojo se ac vará 5 Aléjese del controlador para que el dióxido de carbono de su respiración y el m...

Page 4: ...contrôleur fonc onner normalement pendant 10 minutes 4 Tournez la roule e du Point de réglage dans le sens inverse des aiguilles d une montre et la roule e de la bande morte dans le sens des aiguilles Trois secondes après avoir réalisé ces réglages de l unité le contrôleur se me ra sur le mode de calibrage et le voyant rouge s éclairera 5 Éloignez vous du contrôleur afin que le dioxyde de carbone ...

Page 5: ...vollständig entgegen des Uhrzeigersinns Nachdem diese Einstellungen durchgeführt wurden wird sich der Regler nach Ablauf von Operation 3 Sekunden auf die Betriebsart des Kalibrierens stellen und das rote LED Licht wird aufleuchten 5 En ernen Sie sich vom Regler damit das durch Ihren Atem und Ihre Bewegung ausgesendete Kohlendioxid die abzulesenden Werte nicht beeinflusst 6 Überprüfen Sie ob sich d...

Page 6: ...ar r de la fecha de compra El uso erróneo el abuso o el incumplimiento de las instrucciones no están cubiertos Si ene alguna duda llámenos al 1 800 634 9990 para realizar una evaluación de la garan a después contacte con el lugar original de la compra para llevar a cabo la devolución No se aceptarán devoluciones desautorizadas Guarde su recibo factura ya que es necesaria una copia para las tareas ...

Page 7: ...truc ons is not covered Do not open or try to repair any part of the controller Any a empt to do so voids the warranty If you have a concern call us at 1 800 634 9990 for a warranty assessment then contact the original place of purchase for a return Unauthorized returns will not be accepted Save your receipt invoice a copy is required for all warranty work ...

Reviews: