5.

 

Place the Inner Roof Connection Bracket under the “D1-D2” 2x4 connection on the inside.  Fasten the 
Inner Roof Connection Bracket into place (Fig. 1E) using hex headed screws. 

6.

 

Attach an Outside Corner Anchoring Bracket to an “A#-B” (corner) assembly (Fig. 1A) using two (2) 
hex headed screws.  Fasten the bracket to the concrete using one (1) anchor.  Fasten one (1) Outside 
Corner Anchoring Bracket at both “A#-B” (corner) assemblies on one side.  

A.

 

Attach Inside Anchoring Brackets to the “B” (side) panels at the bottom, inside at the concrete (Fig. 1B) 
using  two  (2)  hex  headed  screws  per  bracket.    Fasten  them  to  the  concrete  using  one  (1)  anchor  per 
bracket.    Fasten  Inside  Anchoring  Brackets  to  the  “B”  panels  and  concrete  along  one  side  of  the 
enclosure.  

B.

 

Insert Inside Roof Clips into the “D#” (roof) panels at the “B” (side) panel studs (Fig. 1C).  Attach the 
clips to the “B” panels using one (1) hex headed screw per clip.  Fasten Inside Roof Clips to the “B” and 
“D#” panels along one side of the enclosure.  

C.

 

Repeat Steps 6, 6A and 6B on the other side and end of the enclosure. 

7.

 

Install  Roof Cover Plates  on  the “D1-D2” roof seams (Fig.  1D) using two (2) hex headed screws per 
plate.  

8.

 

Provide a ground-fault interrupter device in all electrical circuits per all applicable codes.  Install the 
heater(s) as per the manufacturer’s instructions and governing local and national codes.  

9.

 

For  maximum  protection,  it  is  suggested  that  the  area  between  the  bottom  of  the  enclosure  and  the 
concrete base should be caulked except for the “C” panels.  DO NOT CAULK THE BOTTOM OF 
THE “C” PANELS.  

10.

 

REMOVE  THE  PVC  MASKING FILM IMMEDIATELY AFTER INSTALLATION.  If the panels 
get wet with the masking film in place, water will irreversibly stain the panels.  Summertime heat will 
bake the masking film onto the panels.  

Summary of Contents for SAFE-T-COVER 600TD Series

Page 1: ... ID and 3 longer than ID 2 The PVC masking film will help to protect the finish of the metal panels during installation These coatings should be left intact and removed only after assembly of the enclosure is complete A Stand both sets of A1 A2 panels firmly together Fasten the panels together through the holes provided on the inside of the panels using hex headed screws Make sure the panels are p...

Page 2: ... adjacent panels prior to attaching any bracket to the concrete 4 Set the C access panels in place with about a 3 16 gap on each side of the C panels as the roof is assembled A Set the D1 roof panel on a B A1 A2 B side end side assembly Fasten the D1 roof panel to the B A1 A2 B side end side assembly through the holes provided Fig 1 using three 3 hex headed screws B Insert an Inside Roof Clip into...

Page 3: ...e B panels and concrete along one side of the enclosure B Insert Inside Roof Clips into the D roof panels at the B side panel studs Fig 1C Attach the clips to the B panels using one 1 hex headed screw per clip Fasten Inside Roof Clips to the B and D panels along one side of the enclosure C Repeat Steps 6 6A and 6B on the other side and end of the enclosure 7 Install Roof Cover Plates on the D1 D2 ...

Page 4: ...ld include A 2 A1 end Panels B 2 A2 end Panels C 4 B side Panels D 1 C removable access Panel E 1 Cw d removable access Panel F 1 D1 roof Panel G 1 D2 roof Panel H 4 Outside Corner Anchoring Brackets 1 x 1 I 6 Inside Anchoring Brackets 3 x 3 J 6 Inside Roof Clips K 2 Roof Cover Plates L 1 Inner Roof Connection Bracket M 1 Package of Anchors N 1 Package of Hex headed screws O 1 Masonry Bit P 1 Magn...

Reviews: