background image

If you have further questions regarding installation after thoroughly reading this guide: The HydroCare Service  

Department can be reached Monday – Friday, from 9am – 4pm PST at 253-887-7625, 888-963-6178,  or at  

[email protected]

.  

 

1.  Installation of Water ShutOff Valve at the unit is recommended for media replacement changes and for emergency  

     shut off water. 

2.  Turn off your water supply. Turning off your water heater is recommended. 

3.  Release water pressure by opening a faucet. 

4.  Attach water source to the Inlet.  

NOTE:

 1” threaded male adapter to existing inlet size and type is required 

5.  Attach water source to the Outlet. 

NOTE:

 Existing outlet pipe size smaller or greater than 1” will require a bushing.   

6. Remove the plastic wrappings from the filters and place the housings in line with your labeled lids, inlet to  

     outlet.  The HC-DP-CRLD filters are identical.  

NOTE:

 

You also need to remove the ‘THIS END UP’ sticker on the Pre- 

     Filter and be sure ‘this’ end is placed upright.

 

7.

Use your finger to lubricate  the surface of each O-ring with silicon grease provided  

        in caps.  

NOTE:

 

This step is important to ensure proper housing seal.  Make certain  

        the O-ring is seated level in the groove.

  

8.  Screw each housing onto its lid and hand-tighten.  Use wrench to make snug. 

9.  Close open faucet.  You may now turn your water on.  Go slowly and check for leaks.  

NOTE:

  

A carbon cartridge may     

     contain carbon fines (very fine black powder).  After installation, run water for 5 minutes before using the water.     

     The water is safe to drink.

   

10. If water leaks at housings:  Shut off water and release pressure.  Tighten slightly with wrench.  Do not over tighten.   

      Reapply silicon  to the O-ring if leak persists.   

11. If water leaks at fittings:  Shut off water at the house water supply shutoff valve, disassemble, and begin Installation    

      Instructions by re-taping the nipples. 

12. Turn your water heater on.  

13. Fill out the enclosed Warranty Card and mail. Your serial number is located on the underside of the Bracket and on   

      the box your Dualplexx® came in.  If you include your email on the warranty card, you will receive media replacement 

      reminders.  Make note of your installation date and record your media replacement dates for your own records. 

Connection Instructions

 

  If pressure loss is noticed, the HC-DP-PRE (Pre-Filter) may need to be replaced.  The Pre-Filter may need to be     

     replaced more often than the  HC-DP-CRLD filters. 

  Changes in the taste and/or odor of the water indicates it is time to change the HC-DP-CRLD filters.  

Replacement Filter Guide

 

Reviews: