HA 350 (20-35x21) & HA 550 PUMPS (20-55xx1) FOR WHIRLPOOL 

 

Direction for use 

Electrical supply 220-240VAC / 50Hz. 

The pumps must be installed in a place, where there is easy access to the terminal box. 

If the cable is replaced, the square dimension of the cable must not be reduced. 

The cables must be of a minimum type H05VV-F fully connected to earth.  

Ensure that the cable gland is fully tightened. 

The pump must be protected by a fuse. 

In order to separate the pump from the mains, a suitable ground fault circuit interrupter, with at least 3 
mm break distance on each terminal in the present electrical installation, must be installed. 

External earth screw on the motor to be used for connection of external equipotential bonding. 

 

Attention!! 

A.  The pumps must not be used for liquids in excess of 60°C. 
B.  It is recommended to connect the pump via an electronic control box that has a detection device fitted to 

detect the absence of liquid. 

C.  The installation must be according to the normal power indicated on the label. 
D.  It is recommended that you consult a state-registered electrician. 
E. If 

the 

supply cord

 is damaged, it must be replaced by the manufacturer, its service agent or similarly 

qualified persons in order to avoid a hazard. 

F.  Locate the pump in a dry area with good ventilation. 
G.  The ambient temperature must not exceed 40°C. 
H.  The pumps are solely for use in whirlpool and spa systems. 
I. 

This appliance is not intended for use by persons, including children with reduced physical, sensory or 
mental capabilities or lack of experience and knowledge, unless they have been given supervision or 
instruction concerning use of the appliance by a responsible for their safety. 

J.  Children should be supervised to ensure that they do not play with the appliance.  

 

Mounting of pump 

There are different ways of installing the pump: 

 
 
1. 

The easily accessible rubber feet allow quick installation of the pump, 

by screwing 4 pcs. of M6 bolts up into the nuts, that are integrated in 
the rubber feet.  

 
 
 
 
 
 

 

 

 

 
2. With a mounting plate 20-0400, you simply screw one M10 bolt or a 
threaded pole up into the nut that is integrated in the plate, and the 
pump is in place.  

 
 
 
 

Summary of Contents for HA 350 Series

Page 1: ...ust be according to the normal power indicated on the label D It is recommended that you consult a state registered electrician E If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard F Locate the pump in a dry area with good ventilation G The ambient temperature must not exceed 40 C H The pumps are solely ...

Page 2: ...dem Anschlussetikett angegebenen Spannung übereinstimmen D Wir empfehlen die Installation von einem Spezialisten vornehmen zu lassen E Wenn das Anschlusskabel beschädigt ist muss es vom Hersteller einem seiner Subunternehmen oder einem anderen Spezialisten ausgetauscht werden F Platzieren Sie die Pumpe auf einer trockenen Fläche mit guter Belüftung G Die Umgebungstemperatur darf 40 C nicht übersch...

Page 3: ...uissance normale indiquée sur la plaque signalétique D Il est recommandé de consulter un électricien agréé E Si le câble d alimentation est endommagé il doit être remplacé par le fabricant son agent de service ou des personnes qualifiées afin d éviter tout danger F Installer la pompe dans un endroit sec et bien aéré G La température ambiante ne peut pas dépasser 40 C H Les pompes sont exclusivemen...

Page 4: ... pumpens mærkeeffekt D El installationen skal udføres af en autoriseret elektriker i henhold til landets reglementer E Hvis tilledningen bliver beskadiget skal den udskiftes af fabrikanten eller hans serviceværksted eller af en tilsvarende uddannet person for at undgå at der opstår fare F Pumpen installeres på et tørt og godt ventileret sted G Omgivelsestemperaturen må ikke overstige 40 C H Pumpen...