Daily:

When fi nished using the pump for the day, run the pump two to four minutes with the select valve and 
nozzle in rinse position, to purge chemical from the unit.  See Fig. G.
Set the nozzle to “S” (keep the select valve in the rinse position) and run for ten seconds.
Turn the unit off with the switch.  Relieve the pressure in the discharge hose by pulling the trigger on the 
spray attachment after the switch has been turned off.  A small amount of water will discharge.
Check the unit for any damage or leakage.
If the unit is going to be stored where it can freeze, drain the water reservoir and run the pump until there 
is no more water in the system.  Allow the system to thaw before you start the pump.
Plug the unit into a 120 Volt outlet to recharge the battery.  The indicator light on the charger will be red 
while the battery is charging, and green when the battery is fully charged.  Leave the charger plugged in 
during long term storage to maintain the battery at peak capacity.  Note:  It is not necessary to fully dis-
charge the battery before recharging.

NOTE:  Failure to follow this procedure after use will void the warranty on the pump.

1.

2.
3.

4.
5.

6.

Maintenance:

The power switch is lighted when it is in the “ON” position. 
The pump will run when the trigger on the spray attachment is pulled and stop when it is released.
The rollover valve on the outlet of the spray attachment selects between the two attached spray 
nozzles.  “S” should be used when applying either product, “R” is used for rinsing.  The rinse is a fi ne 
spray pattern, while the “S” is a pattern that is more coarse.
Run the unit approximately 10 seconds to fl ush prior chemical from hose.

NOTE:  To apply either chemical you must use nozzle “S” for proper dilution.

1.
2.
3.

4.

Normal Operation:

CAUTION:  Continuous cycling of the pump (continuous, rapid on/off cycles) indicates a problem 
with the unit.  Have the unit serviced immediately.

6

Out of water/chemical indication:

When the system runs out of either water or chemical, air will enter the water stream and it will become 
“rough.”  The pump may also continue to run when the trigger is released.  Turn off the power immedi-
ately, fi ll the water reservoir and/or replace the empty product container, and repeat the priming operation.

CAUTION:  Do not operate unit while the charger is plugged into an electrical outlet.  If unit does 
not operate unless plugged in, check that the battery terminals are connected (see initial set up 
proceedure on page 4).

Summary of Contents for ICS 8950

Page 1: ...Integrated Cleaning System Rechargeable Battery ICS 8950 ...

Page 2: ...spense cleaners and chemicals in accordance with manu facturer s instructions observe safety and handling instructions of the chemical manufacturers equipment after each use to maintain proper operation Unit with integral 12 5 gallon water reservoir Battery charger installed Spray attachment w 2 nozzles installed 15 ft discharge hose installed 2 Bottle holders Metering tip kit Instruction manual 2...

Page 3: ...y easier This unit includes the following features 15 ft discharge hose Locking casters Spray attachment with two nozzles solution and rinse Storage for spray bottle Fresh water reservoir 12 5 Gal Chemical bottle holder Top Easy roll wheels 3 Tap style drain Sign hanger Battery Charger On Off Switch Battery Life Indicator ...

Page 4: ...ning and the viscosity of the liquid being siphoned For water thin products the chart can be used as a guideline Because dilution can vary with water temperature and pressure and if the product is noticeably thicker than water dilution rates shown should be viewed as approximate Orifice Size Tip Color Average Dilution Ratio no tip 4 1 0 128 grey 4 25 1 0 098 black 4 5 1 0 070 beige 4 5 1 0 052 red...

Page 5: ...un for a short time then stop The pump will run until the discharge pressure reaches the factory set point The pump will then turn off until the trig ger on the spray attachment is activated Direct the spray nozzle into a drain or other con tainer and pull the trigger Run until a steady spray pattern is established without air in the water stream Release the trigger The pump should stop almost imm...

Page 6: ...rranty on the pump 1 2 3 4 5 6 Maintenance The power switch is lighted when it is in the ON position The pump will run when the trigger on the spray attachment is pulled and stop when it is released The rollover valve on the outlet of the spray attachment selects between the two attached spray nozzles S should be used when applying either product R is used for rinsing The rinse is a fine spray pat...

Page 7: ...heck battery life indicator if necessary recharge Pump pulses There is a pressure switch in the pump If the pump is pulsing this switch is cycling and the life of the pump will be greatly reduced Have the pump serviced Pump not running Battery is dead recharge Loose battery connection check that both terminals are connected Pump not priming Make sure the water feed line is untangled and lying at t...

Page 8: ...hose replacement black 9 10092252 On off switch replacement kit 10 10091867 Caster replacement kit set of 2 11 10091866 Wheel replacement kit set of 2 12 10091861 Fill port cap 13 10092217 Sign hanger 14 10092258 Mop clips set of 2 15 10092266 Bottle holder set of 2 16 90084615 Tap style drain 17 690014 Metering tip kit 18 10076302 Foot valve EPDM 19 10092251 Chemical feed line kit Single 20 10092...