19
Jets 1 control
Your spa is equipped with a two speed motor on pump 1. Depress the JETS1 pad to
turn on pump 1(low speed), depress the JETS1 pad a second time to turn on pump
1(high), depress the JETS1 pad again to turn pump 1 off. Corresponding spa jets will
operate when pump 1 is on (low or high). Anytime Pump 1 has been manually turned
on, it will automatically turn off after approximately 15 minutes on high speed and 4
hours for low speed. LED light JETS1 is on when the pump 1 is on.
Aux. control
(if spa equipped with 2 speed pump or a single speed pump)
If your spa is equipped with a two speed pump, depress the AUX pad to
turn pump to (low speed) - if a single speed pump, depress AUX pad once to turn
pump on, depress the AUX pad a second time to turn 2 speed pump to (high) depress
AUX pad once to turn single speed pump off. Depress the AUX pad again to turn 2
speed pump off. Corresponding spa jets will operate when pump 2 is on (low or high).
Anytime Pump 2 has been manually turned on, it will automatically turn off after
approximately 15 minutes. LED light AUX is on when the pump 2 is on.
Blower control
(if equipped with Air blower)
If your spa equipped with an Air Blower, depress the BLOWER pad to turn on the
Blower, depress the BLOWER pad a second time to turn the Blower off. Corresponding
air jets will operate when Blower is on. Anytime Blower has been manually turned on, it
will automatically turn off after approximately 15 minutes.
Mood Light control
If your spa equipped with a mood Light, depress the LIGHT pad to turn on the Light,
depress the LIGHT pad a second time to turn the Light off. The spa mood light prepro
grammed with assortment of lighting effects. When you turn Light off and turn on within
5 seconds it advances to the next effect. When you turn the Light off for more than 5
seconds, it remembers that last effect you selected. The next time you turn on the
Light, it displays same effect. The Light will automatically turn off after approximately 4
hours. For Standard Light application every time you depress the LIGHT pad the Light
will turn on and off.
Spa Mode selection
Depressing the MODE pad will allow you to select either "Standard", "Economy" or
"Sleep" mode. In Standard mode the water temperature is held to the set temperature
all time. After the set temperature is reached, the heater turns off and the 24 hour circu
lation pump and ozone generator continue to operate to oxidize and sanitize the spa
water. In Economy mode the 24 hour circulation pump and ozone generator continues
to operate and heater will turn on only during a programmed filter cycles. The heater in
Economy mode will operate when actual water temperature of the spa is below the set
point temperature and spa is in filtration cycle. Default setting of filtration cycle is 2
hours, twice per day. In Sleep mode the 24 hour circulation pump and ozone generator
continues to operate and heater will turn on only during a filtration cycle and the water
temperature in spa is 20F below the set temperature.
Circulation Pump
Your system is equipped with a 24-hour circulation pump which provides 24 hour con
tinuous water circulation and filtration. The spa's entire contents is completely filtered
50-80 times each day . It works like this: a dedicated, energy efficient, quit circulation
OPERATING INSTRUCTIONS - HS200 M7