20
Page
For
multiple
sidewall exhaust termina
tions
(e.g.
Multi-
Unit Systems), an exhaust termina
tion
must be at least 1
ft.
(305mm) away from another exhaust termina
tion.
An
exhaust termina
tion
must also be at least 2
ft.
(610 mm)
away from an inside corner. (If the adjacent wall is less than
2
ft.
(610 mm) of length, the minimum required distance
away from the inside corner will be equal to the length of
that adjacent wall.)
For
multiple-
unit, direct
-v
ent sidewall termina
tions
that
combine the intake and exhaust into a single
pen
etra
tion
,
space
each direct
-v
ent termina
tion
at least 1
ft.
(305 mm)
away from each other, no ma
tt
er the orienta
tion.
A direct
-
v
ent termina
tion
must also be at least 2
ft.
(610 mm) away
from an inside corner. (If the adjacent wall is less than 2
ft.
(610 mm) of length, the minimum required distance away
from the inside corner will be equal to the length of that
adjacent wall.)
Exhaust
termina
tion
Inside
corner
1
ft.
(305 mm) min
2
ft.
(610 mm) min
1
ft.
(305 mm)
min
Combined
intake and
exhaust
termina
tion
Inside
corner
1
ft.
(305 mm) min
2
ft.
(610 mm) min
1
ft.
(305 mm)
min
For direct
-v
ent sidewall
termina
tions
that use two
sepa
rate
pen
etra
tions
for
the intake and exhaust,
kee
p
the termina
ti
on
clearances shown in the
diagrams on the right.
Please follow all local and na
tional
codes in regards to
p
r
oper
termina
tion
clearances. In the absence of such codes, the clearances below can be used as
guidelines. Local codes
supe
rsede these guidelines.
CAUTION
1
ft.
(305 mm) min
0.5
ft
(159 mm) min
Exhaust
Intake
Exhaust
Intake
<Case 2>
1
ft.
(305 mm)
min
0.5
ft.
(159 mm) min
0.5
ft.
(159 mm)
min
Exhaust
Intake
Exhaust
Intake
<Case 1>