2.SPECIFICATIONS
2.1 Performance data of Swimming Pool Heat Pump Unit
*** REFRIGERANT : R32
4
See the drawing of the units
See package lable
see nameplate
see package label
Heating: Outdoor air temp: 27
/24.3
, Inlet water temp:27
Outdoor air temp: 15
/12
, Inlet water temp:25
Operating range:
Ambient temperature:-15-43
℃
Water temperature:9-40
UNIT
Heating capacity
(27/24.3
Heating Power Input
COP
Heating capacity
(15/12
Heating Power Input
COP
Power Supply
Compressor Quantity
Compressor
Fan Number
Fan Power Input
Fan Rotate Speed
Fan Direction
Noise
Water Connection
Water Flow Volume
Water Pressure Drop(max)
Unit Net Dimensions(L/W/H)
Unit Ship Dimensions(L/W/H)
Net Weight
Shipping Weight
kW
Btu/h
kW
kW
Btu/h
kW
W
RPM
dB(A)
mm
3
m /h
kPa
mm
mm
kg
kg
PV 17
3.600-16.50
12240-56100
0.2600-2.740
13.8-6.02
1.940-12.30
6596-41820
0.3000-2.680
6.47-4.59
230V~/50Hz
1
rotary
1
60
700-800
horizontal
45-54
50
7.5
4.0
PV 13
3.080-13.50
10472-45900
0.2400-2.230
12.8-6.05
2.370-10.07
8058-34238
0.3900-2.210
6.08-4.56
230V~/50Hz
1
rotary
1
60
600-750
horizontal
44-53
50
6.0
3.0