Operation Procedures
Knowledge of the proper operation of the MX200H is required to ensure
user safety and efficient performance of the extractor.
SET UP AND OPERATION
1. Electrical Cords:
Two 25’ power cords are supplied with the Nautilus MX200H. Cord#2 will power the heater and the waste
pump if so equipped.
The amperage required by each cord requires that the two cords be plugged into separate circuits:
•
Cord #1 (Left side) Powers vacuum #1, vacuum #2, the Solution Pump, and the cooling fan. Must be
plugged into a 20amp circuit.
•
Cord #2 (Right side) Powers 1750W heater and waste pump if so equipped. When both the heater and
waste pump are used, Cord #2 must be plugged into a 20amp circuit. If only the heater or only the waste
pump are used Cord #2 can be plugged into a 15amp circuit.
20amp circuits are usually found in kitchens and bathrooms.
An overloaded circuit will not always trip
the circuit breaker immediately, but it may not provide sufficient voltage for proper operation and the breaker
may trip eventually.
Plug the two power cords into two outlets from different circuits. If the Dual Circuit Indicator green light
fails to light, you may be on the same circuit and may need to select a different plug for one of the cords. If
the Dual Circuit Indicator green light comes on, you are plugged into two different circuits. Proceed with
your set-up procedure.
(Dual Circuit Indicator light may take up to 30 seconds to recognize the two circuits and turn ON.)
If a circuit breaker trips or the pump circuit breaker trips during operation, reset the breakers and move the
cord to another outlet as needed.
When operating the MX200H with the 1750W heater DO NOT
turn the heater on until after the pump has been primed and solution hose and tool
connected – Steps #3, #4 & #5.
Power Cord –
1696-6412
25’ – 12 gauge M-F Plugs
Cord #2
Dual Circuit Indicator Light
Cord #1
Summary of Contents for Nautilus MX200H
Page 1: ...1 LMANN07 Revised 02 16 2018 Nautilus MX200H Operating Manual ...
Page 37: ...37 OPTIONAL AUTO FILL FLOAT VALVE ASSEMBLY NM5740 ...
Page 38: ...38 Optional Pump Out Pump AP37 PARTS ASSEMBLY ...
Page 39: ...39 1 2 5 6 7 8 9 11 3 8 9 12 4 4 3 10 39 8 9 8 9 2 ...
Page 43: ...43 48 49 49 47 47 47A 47 47 47A 47A 51 51 37 9 54 64 9 54 64 52 VACUUM MOUNTS CONNECTIONS ...
Page 48: ...48 96 91 97 9 94 105 OPTIONAL PUMP OUT CONNECTIONS 99 95 93 118 118 ...
Page 49: ...49 FLOW 81 92 91 99 96 97 105 13 14A 14 95 OPTIONAL PUMP OUT PARTS 1 9 97 9 39 118 ...
Page 50: ...50 HEATER PARTS 111 113 114 112 2 115 2 116 2 42 42A 117 ...