PROBLEM
Q
Machine does not start and makes NO noise.
Q
Machine does not start and makes a grunting sound.
Q
Only one brush turns.
Q
Th e machine turns on when the handle is in the upright
and locked position.
Q
Th e machine bounces roughly when in use.
SOLUTION
A
Wait 30 seconds if the machine is warm. Push the motor
protector reset button (on the side of the machine). Use
a small object, like a pencil, to be sure to press it in far
enough. (illustrated — Operations #2)
A
Tilt the machine toward the foot pedal end of the ma-
chine, and allow the brushes to rotate at full speed before
lowering the machine slowly back onto the carpet.
A
One or more gears have stripped and need to be re-
placed before use. (Consult your local distributor).
A
Replacement of the foot pedal is needed. (Consult your
local distributor.)
A
Inspect the brushes for directional set from scrubbing in
one direction too long.
• Inspect the axles and brush end caps for wear which will
cause a vibration.
• NOTE: To prevent directional set, rotate both brushes
end-to-end. Always perform this action at day’s end or
aft er 2–4 hours of continuous use.