Hydrel 4600 KM Installation Instructions Manual Download Page 4

  1.  Be sure power is turned off.
  2.  Place provided gasket in black of wall mount cover (WMC) plate, and pull fixture wires through WMC
  3.  Attach fixture to threaded opening in the WMC.
  4.  Make all electrical connections to the fixture. Attach supply 

LINE

 wire to the black wire from the fixture. Connect 

the Neutral wire from the supply to the white wire of the fixture. Be sure that the ground wire is attached to an 

approved grounding source.

  5.  Attach WMC to mounting surface using the two screws provided or appropriate hardware to support the fixture.
  6.  Loosen the allen screw in the side of the knuckle and aim the fixture. Retighten the screw in the knuckle.
  7.  Unscrew the fixture lens cover and install proper lamp type (by others).
  8.  Replace lens cover making sure that the cover fits snugly.

Wall Box 

(by others)

Loosen screw in 

knuckle to aim 

fixture

Lens cover

Fixture 

attaches here

WMC

4600 

Fixture

Wall Box 

(by others)

Mounting 

screws 

(provided)

INSTALLATION DIAGRAM

WALL MOUNT COVER

(WMC)

 

  4600 KM

KNUCKLE MOUNT

INSTALLATION INSTRUCTIONS

Installation should be performed by a qualified 

electrician in accordance with the National Electrical Code 

and relevant local codes.

*IMPORTANT:

Junction Box/Ballast Box must be water tight.  

Seal all conduit entries with suitable compound 

(e.g. Hydrel PC-21 re-enterable potting compound) 

to prevent moisture penetration from the supply 

conduit system.

NOTE:  HYDREL RESERVES THE RIGHT TO MODIFY SPECIFICATION 

WITHOUT NOTICE. Any dimension on this sheet is to be assumed as a 

reference dimension: “Used for information purposes only. It does not 

govern manufacturing or inspection requirements.” (ANSI Y14.5-1973)