Hydrel 4600 KM Installation Instructions Manual Download Page 2

HID 

(with surface mounted conduit)

 

1.  Be sure power is turned off 

 

2.  Attach fixture to Ballast box cover plate. (See “fixture head only” directions).

 

3.  Pull wires from surface conduit through hole in side of Ballast Box. 

 

4.  Attach the Ballast box to the wall using suitable screws (screws by others). Be sure to seal around 

mounting screws to prevent water entry.

 

5.  *Make electrical connections to the fixture. Attach supply 

LINE

  wire to the wire labeled 

LINE

  from the 

ballast box. Connect the neutral wire from the supply to the white wire in the Ballast box. Be sure that 

the ground wire is attached to an approved grounding source.    

 

6.  Attach the fixture and cover plate to the Ballast box using the screws provided.

 

7.  Loosen bolt in knuckle and knuckle stem set screws to aim fixture. When aimed properly, retighten the 

knuckle bolt and set screws.

 

8.  Unscrew lens cover. Install Lamp (by others) in socket. Replace lens cover.

Note:  Use only manufacture recommended lamps

CONDUIT ENTRY LOCATION

CONDUIT ENTRY LOCATION

SSB BALLAST BOX

MOUNTING 

HOLES

MOUNTING 

HOLES

INSTALLATION DIAGRAM

 

  4600 KM

KNUCKLE MOUNT

INSTALLATION INSTRUCTIONS

Installation should be performed by a qualified 

electrician in accordance with the National Electrical Code 

and relevant local codes.

*IMPORTANT:

Junction Box/Ballast Box must be water tight.  

Seal all conduit entries with suitable compound 

(e.g. Hydrel PC-21 re-enterable potting compound) 

to prevent moisture penetration from the supply 

conduit system.

NOTE:  HYDREL RESERVES THE RIGHT TO MODIFY SPECIFICATION 

WITHOUT NOTICE. Any dimension on this sheet is to be assumed as a 

reference dimension: “Used for information purposes only. It does not 

govern manufacturing or inspection requirements.” (ANSI Y14.5-1973)

©2014 Acuity Brands Lighting, Inc.
6/19/14
INS-4600_KM

9144 Deering Avenue  |  Chatsworth, CA 91311

Phone: 866.533.9901  |  Fax: 866.533.5291 

www.hydrel.com

CONDUIT ENTRY

LOCATION

BALLAST BOX 

COVER PLATE

FIXTURE HEAD

KNUCKLE STEM

BALLAST BOX

KNUCKLE STEM SET SCREWS (2)