Page 8-1 : CTS 330 Owner’s Manual
Hot Carbonating Truckmount System
CTS 330
Electrical System
The CTS 330 electrical system, in keeping with the entire machine concept, has been kept
to a minimum so as to keep any necessary troubleshooting as easy as possible.
The entire electrical system operates on 12 volts DC which is provided by a battery. Bat-
tery levels are sustained by a 16 amp alternator inside the engine.
When a new battery is installed, check that it is properly charged before installation or
damage to the charging system may occur.
The orange wire going from the engine starter solenoid to terminal #5 on the ignition
switch is a fusible link and provides protection to the electrical system in case of failure.
Ignition Switch:
Table 8-1
Table 8-2
CAUTION
!
Switch Position Continuity
1. Off
1 + 3 + 6
2. Run
2 + 5 + 6
3. Start
2 + 4 + 5
Terminal No.
Wire Color
Function
1
Orange
To Solenoid (Battery Post)
2
White
To Main Fuse
3
Black
Engine Kill Lug
4
Yellow
To Solenoid (Start Position)
5
Brown
To Regulator Ground
6
Red
To Regulator / Rectifier