41: CTS 400 Flex Owner’s Guide
Adjustment
1. If the pump continues to run for longer than 3 to 5 seconds, turn the screw
counterclockwise until the pump switches off (see Figure 13).
2. If the pump switches off as soon as the hose is disconnected (less than 3 to 5
seconds), turn the pump screw clockwise one complete turn.
3. With the pump still on, reconnect the solution hose onto the Flex unit (see
The pump should switch on.
4. Repeat steps 1 through 3 on this page until the pump switches off within 3 to 5
seconds after the hose is disconnected.
CLOCKWISE
COUNTERCLOCKWISE
Figure 13. Insert Hex L-Key and Turn It Counterclockwise/Clockwise