39: CTS 400 Flex Owner’s Guide
PUMP TUNING INSTRUCTIONS
Pump tuning for the CTS 400 Flex allows the pump pressure switch to turn off when there
is no flow out of the tool. This reduces the pump operating temperatures and increases
the pump durability.
Pump tuning should be performed every 60 days.
The pump pressure setting adjustment is performed by turning the hex screw, which is
close to the center of the pump head, with a hex L-key, provided in
the Flex Installation
Kit -
(see Figure 12).
• Clockwise increases the pressure
• Counterclockwise decreases the pressure.
Tools required include:
•
1/16” hex L-key (one is provided with each pump for your convenience in
Installation Kit, P/N 000-078-934).
• Solution hose
• Cleaning tool (upholstery tool/ wand/ rotary cleaning tool) to allow solution to
flow out
•
Container to collect solution flowing out of the tool.
CLOCKWISE INCREASES PRESSURE
COUNTERCLOCKWISE
DECREASES PRESSURE
Figure 12. Location of Pump’s Hex Screw