Page 3-1: Operating Instructions
Boxxer H
2
O
Operating Instructions
Start Up
1. Perform daily and periodic maintenance as specified in this Owner’s Manual.
The machine cannot be
run
in the “IDLE” position for water recovery. This
will void the warranty.
Note: Never run machine on any speed other than full throttle. Running at any
other speed will void the warranty.
Flood Extraction
1. Start the engine with the THROTTLE cable to the
“IDLE”
position.
Allow the machine to run in idle for
2 - 3 minutes to warm up.
2. Connect required length of hoses.
3. Connect wand or tool.
4. Pull the THROTTLE cable to
the “HIGH”
position.
5. If used, turn PUMP OUT switch to “ON” .
6. Commence water extraction.
Shut Down
1. Remove the vacuum hose.
2. At this time, the blower should be lubricated with an oil-based lubricant. See
Lubrication
in the Blower Operation and Maintenance Manual included in Sec-
tion 8 of this document.
3. Lower the engine RPMs to idle.
4. Turn the key off.
5. Drain the vacuum tank. The vacuum filter should be cleaned prior to mobiliza-
tion of the van.
Note:
In accordance with the EPA, state and local laws,
do not dispose of
waste
water into gutters, storm drains, streams, reservoirs, etc.
6. Perform daily maintenance as prescribed in this manual
.