5-13: Machine Maintenance
Machine Maintenance: 5-12
Extracting Seals
With manifold removed from crankcase:
1. Insert proper extractor collet through main seal retainer (see Figure 5-11).
2. Tighten collet and extract retainers and seals.
The Teflon seals of the HT series will be damaged during disassembly so new
ones with have to be installed.
Figure 5-11. Extract Retainers and Seals
Replacing the Seal Assemblies
Only one seal kit is necessary to repair all the seals in the pump (see Figure 5-12). Use
an insertion tool for seal installation
To install a seal assembly:
1.
Apply a film of O-ring grease on the O-ring on the outside of the new high pressure seal.
2. Insert the high pressure seal into the cavity with the “U” shape down.
3. Press high pressure seal into place.
4.
Apply a film of grease on the O-ring on the brass retainer (see
Figure 5-13. Install Seal Assembly Using O-Ring Grease
Figure 5-12. Seal Kit and Insertion Tool for Seal Installation
Summary of Contents for Boxxer 423s
Page 5: ...Boxxer 423S Owner s Manual vi ...
Page 15: ...General Information 1 18 ...
Page 25: ...Cleaning Information 3 10 ...
Page 29: ...Operating Instructions 4 6 ...
Page 43: ...6 3 Water and Chemical System Figure 6 1 Flow Diagram View 1 of 3 000 179 045 Rev A ...
Page 45: ...Water and Chemical System 6 6 ...
Page 49: ...Electrical System 7 6 ...
Page 56: ...Systems Troubleshooting 8 12 ...
Page 85: ...9 56 Assemblies and Parts Lists ...
Page 87: ...How to Order Parts 10 2 ...
Page 90: ...Warranty Information 11 4 ...