2
Setting the flow control valve [
5.9.1 Filter housing with flow control valve (OLF-xx-E-Z)
The flow control valve on the filter housing keeps the flow rate
constant by means of a control process. The flow rate is al-
most entirely independent of the pressure and viscosity.
The flow rate is factory-set to 5 l/min. The flow control valve's
setting range ranges from 4.0 … 5.2 l/min.
Fig. 15:
Filter housing with flow control valve
Pos. Description
(A) Adjustment screw
(B) lock nut