5 | Setting up / assembly / integration of the filter unit
HYDAC FILTER SYSTEMS GMBH
38 / 80
BeWa OF5 CM 3580053c en-us print
5.2 Measure dynamic pressure or differential pressure
If pressure is measured in a hydraulic system, the type of mea-
surement such as dynamic pressure or differential pressure as
well as the measurement point MP is critical, as shown in the
following figure.
Fig. 12:
Measure dynamic pressure or differential pressure
MP Measurement point
∑∆p = Differential pressure,
total
MP1 = Back-pressure
∆p1 = Differential pressure
MP2 = Back-pressure
∆p2 = Differential pressure
MP3 = Back-pressure
∆p3 = Differential pressure
MP4 = Back-pressure
p4 = Back-pressure
In the example, the dynamic pressure at the first measurement
point MP1 shows the sum of the subsequent differential pres-
sures Δp1, Δp2 and Δp3 and the dynamic pressure p4 at the
last measurement point MP4, denoted in the example in simpli-
fied form as ∑∆p.
1
2
3
4
5
6
7
8
9