HYDAC FILTER SYSTEMS GMBH
Installation / Assembly | 5
MoWa LVH-CD-AWD 4650237 en-us web
29 / 52
5.2 Hydraulic installation
In addition to the water sensor and drain valve, the scope of
delivery of the AWD also includes a connector set, depending
on the size of the coalescing housing used. The disposition ac-
cording tom the size is given in the following chapters.
5.2.1 Installation on the vertical LVH-CD 240/440
Install the ball valve (190) for manual drain and the solenoid
valve (100) for automatic drain with the enclosed connections
(80) according to the following figure.
Fig. 6:
Installation of the vertical LVH-CD 240/440
20
Water sensor
21
Sealing ring
80
Connector set
100
Solenoid valve
190
Ball valve
1
2
3
4
5
6
7
8
9
A