HDA 4800
7
Edition: 2017-04-26
HYDAC
ELECTRONIC
GMBH
Part No.: 669868
E
7 Technical data
Input data
Measuring ranges
bar
6
16
40
60
100
250
400
600 1000
1600
2000
Overload pressure
bar
15
32
80
120
200
500
800
1000 1600
2400
3000
Burst pressure
bar
100 200 200
300
500
1000
2000
2000 3000
3000
4000
Mechanical Connection
G1/4 A ISO 1179-2
G1/2 B DIN EN 837
Tightening torque, recommended
20 Nm (G1/4); 45 Nm (G1/2)
Parts in contact with fluid
Mech. connection: Stainless steel
Seal: FPM
Output data
Output signal, permitted load resistance
4 .. 20 mA, 2-Leiter
R
Lmax
= (U
B
– 10 V) / 20 mA [k
Ω
]
0 ..10 V, 3-conductor
R
Lmin
= 2 k
Ω
0 .. 20 mA, 3 conductor (source)
R
Lmax
= (U
B
– 4 V) / 20 mA [k
Ω
]
Accuracy to DIN 16086,
Max. setting
≤
± 0.125 % FS typ.
≤
± 0.25 % FS max.
Accuracy at minimum setting
(B.F.S.L.)
≤
± 0.06 % FS typ.
≤
± 0.125 % FS max.
Temperature compensation
Offset
≤
± 0.005 % FS / °C typ.
≤
± 0.01 % FS / °C max.
Temperature compensation
Over range
≤
± 0.005 % FS / °C typ.
≤
± 0.01 % FS / °C max.
Non-linearity at max. setting
to DIN 16086
≤
± 0.15 % FS max.
hysteresis
≤
± 0.1 % FS max.
Repeatability
≤
± 0.05 % FS
Rise time
≤
1 ms
Long-term drift
≤
± 0.1 % FS typ. / Jah r
Ambient conditions
Compensated temperature range
-25 .. +85°C
Operating temperature range
1)
-40 .. +85 °C / -25 .. +85°C
Storage temperature range
-40 .. +100 °C
Fluid temperature range
1)
-40 .. +100 °C / -25 .. +100 °C
- Marked
EN 61000-6-1 / 2 / 3 /4
mark
2)
Certificate
No.:
E318391
Vibration resistance to
DIN EN 60068-2-6 at 10 ..500 Hz
≤
20 g
Shock resistance according to DIN EN 60068-2-29
≤
100 g / 6 ms
Protection class to DIN EN 60529
3)
IP 65 - Binder 714 M18
IP67 - connection M12x1
- connection EN 175301 - 803
Other data
Supply voltage
When applied according to UL specifications
10 .. 30 V DC 2 conductor
12 .. 30 V DC 3 conductor
– limited energy – according to 9.3 UL 61010; Class 2;
UL 1310/1585; LPS UL 60950
Residual ripple supply voltage
≤
5 %
Current consumption
≤
15 mA
Life expectancy
4)
> 10 million cycles, 0 .. 100% FS
Weight approx.
180
g
Note: Reverse polarity protection of the supply voltage, overvoltage, override and and short circuit protection are provided.
FS
(
F
ull
S
cale) = relative to the full measuring range
B.F.S.L
.=
B
est
F
it
S
traight
L
ine
1) -25°C with FPM seal, -40°C on request
2)
Environmental conditions according to 1.4.2 UL 61010-1; C22.2 no. 61010-1
3)
with mounted female connector having the corresponding protection class
4)
Measuring ranges
≥
1000 bar: > 1 million switching cycles (0 .. 100% FS)
Summary of Contents for HDA 4800
Page 14: ...Notizen Notes Notes ...
Page 28: ...Notizen Notes Notes ...
Page 42: ...Notizen Notes Notes ...
Page 43: ...Notizen Notes Notes ...