Control panel basic (SIMATIC PANEL)
FluidAqua Mobil - FAM10/15-P
en(us)
Page 55 / 124
BEWA FAM10-15-P 4052078 en-us 2015-11-05.doc
2015-11-05
T (Temperature)
MENU1 -> T
F1
F2
F3
F4
START =
Start
FAM
Display in operating status "Ready for operation" and
with the error message "Water content
≥
90%,
measurement with CS not possible".
STOP =
Stop
FAM
is displayed only in the operating status "Starting phase"
and "Automatic operation"
RESET
= Reset error messages
Is displayed only in the presence of faults
MENU1
= Switch to MENU1
Display:
Hysteresis: =
Current
hysteresis setting of the heater.
The hysteresis range is adjustable from 3 to 15°C.
Factory setting: 5%
Temperature Actual: = The heater temperature nominal value can be set
between 0° and 99°C. For details, see page 51.
The safety thermostat responds at 80°C.
Factory setting: 55%.
Temperature Actual: = Current temperature in the vacuum column.
The displayed temperature is measured by a sensor in the sump of the
vacuum column.
The temperature setting can be changed during automatic operation.
START
MENU1
T
Heater: Hysteresis:
5°C
T
t
N
i l 55°C
Ready for operation. Please press Start
STOP
RESET