MultiRheo Filter MRF2
Performing Maintenance
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 21 / 32
MoWa MRF2 3280803c en-us 2011-03-23.doc
2011-03-23
Performing Maintenance
WARNING
Hydraulic systems are under pressure
Danger of bodily injury
►
The hydraulic system must be depressurized
before performing any work on the hydraulic
system.
The MRF is standardly equipped with an electric differential pressure gauge
(red/green) which shows when an element needs to be replaced.
The device can be optionally equipped with an electric back-pressure indicator or
differential pressure gauge.
Every time an element is changed, the housing O-ring(s) is/are to be checked for
any damage and, if necessary, replaced.