MRF 2 NU MultiRheo Filter
2
Included with the Filter As Supplied
Upon receiving the MRF check it for any damage in transit. The MRF may not be set up and
installed unless it is in perfect order. Any damage in transit is to be reported to the forwarding
agent or the HYDAC department in charge immediately; the unit may
not
be commissioned
until this damage is properly remedied.
The MRF comes with the following:
Item
Qty
Designation
1
1
MultiRheo Filter MRF 2 NU
-
1
Operating and Maintenance Instructions (this document)
3 Installation
Before integrating the filter in the system make sure that the rated maximum operating
system pressure does not exceed that of the MRF (see rating plate).
The filter unit has to be set up in a horizontal position on a level surface. The filter unit needs
to be secured to the floor using floor anchors.
Make sure that there is sufficient space above the filter housing as this is
needed for removing the filter elements.
3.1
Hydraulic Hook-up
Connection to the hydraulic system is to be done using flexible tubing or piping. Make sure
that no vibrations or stress/loading from other machinery and equipment are carried over to
the filter housing. If necessary, use expansion joints.
HYDAC Filtertechnik GmbH
en
Page 11
BeWa MRF2NU 3341025 en.doc
2007-09-24