Performing maintenance
Changing the filter element
WARNING
Hydraulic system is under pressure
Danger of bodily injury
►
Depressurize the system before performing any
work on it.
To change the filter, proceed as follows:
1. Close the shut-off valve on IN
inlet and OUT outlet.
2. Depressurize the filter
housing.
Remove the air bleed screw
by turning it counterclockwise
with a 10 mm Allen wrench.
3. Empty the filter housing via
the DRAIN port.
Collect the escaping fluid
(
≈
38 liters) in a suitable
container and dispose of it in
an environmentally correct
manner.
OLFP-6 /X-G/-T001
en(us)
Page 30 / 48
MoWa OLFP-6-x-G-T001 4113643 en-us 2016-04-11.docx
2016-04-11