Page 1: ...LOGO REPLACEMENT MODULE TDE for FAM 5 Installation Manual English translation of original instructions Keep for future reference Documentation no 4359963 ...
Page 2: ...l is meant to be a supplement to the Operating and Maintenance instructions for the FAM Therefore it is limited to the replacement of a defective Logo of the TDE module Everything else such as the explanation of symbols and formal explanations can be taken from the Operating and Maintenance instructions for the FAM The Logo of the TDE replacement module is supplied as a spare part without being co...
Page 3: ...t change due to this with regard to how it is carried out DANGER Electric shock Danger of fatal injury Any work involving the electrical equipment may only be done by a properly trained certified electrician The jobs listed below may only be carried out by properly trained certified electricians who meet the following conditions Only specialist personnel with training as electricians and the follo...
Page 4: ...e TDE module to any direct heat radiation from heating devices If the unit is exposed to or has been exposed to climatic fluctuations temperature fluctuations humidity moisture can condense on or inside the unit unit in a condensation state If there is condensation in or on the unit or if the unit has been exposed to temperature fluctuations allow it to come to to room temperature before starting ...
Page 5: ...h the suitable key 4 Disconnect all cables and connection plugs on the rear side of the Logo of the TDE module Unscrew the set screws out of the holding brackets counterclockwise Remove the four holding brackets and push the Logo of the TDE module from the back to the front out of the cut out section in the door 5 The disassembly of the Logo of the TDE module is complete ...
Page 6: ...ed in place in groove A on the rear side of the module s front panel insert the sealing cord provided in groove A and cut the sealing cord to length so that the joint closes with a tight seal NOTICE Leaks at the Logo of the TDE module Moisture water enters into the E Box via the Logo of the TDE module Ensure that the sealing cord is inserted cleanly If the inserted sealing cord is twisted or if th...
Page 7: ... front through the cut out section in the door Ensure that it is installed with the correct orientation top bottom All ports sockets are located at the bottom 3 Pre mount the set screws provided in the holding brackets The tips of the set screws must point toward the wide ends of the holding brackets 4 Hook the holding brackets into the corresponding recesses in the unit as follows and fix the uni...
Page 8: ...th the four mounted holding brackets fulfil protection class IP65 5 Insert all cables and connection plugs into the corresponding ports on the rear side of the Logo of the TDE module 6 Close the door to the E Box with the suitable key 7 Plug in the power connector and switch the touch panel on at the main switch 8 Check the display of the Logo ...
Page 9: ...o of the TDE module FAM 5 en US Page 9 12 MOWA LogoTDE 4359963 en 2018 05 23 docx 2018 05 08 of the TDE module at starting The user interface starts automatically 9 The assembly of the Logo of the TDE module is complete ...
Page 10: ...e chapters Configuration menu Changing the configuration Exiting the configuration menu in the Operating and Maintenance Instructions for the FAM Model code FAM X X X X X X H X Z X X Product FAM FluidAqua Mobil Filter Size Operating fluid Mechanical type Voltage frequency power supply Filter size fluid filter Vacuum pump Heater Z No heater H Heater for 200 359 V 1 kW for 360 690 V 2 4 kW Control c...
Page 11: ...18 05 23 docx 2018 05 08 Index A AquaSensor 10 C ContaminationSensor 10 Content 2 Control 10 D disassembly 5 F Filter 10 H Heater 10 I installation 7 M Maintenance 2 10 Model code 10 O operating 3 R replacement 1 2 3 10 S Size 10 V Vacuum 10 Vacuum pump 10 ...
Page 12: ...H Industriegebiet Postfach 1251 66280 Sulzbach Saar 66273 Sulzbach Saar Germany Germany Tel 49 6897 509 01 Central Fax 49 6897 509 9046 Technology Fax 49 6897 509 577 Sales Internet www hydac com E Mail filtersystems hydac com ...