FAM 15/30 ATEX
Error messages / troubleshooting
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 46 / 84
BeWa FAM15_30 Atex 3197970c en-us 2012-08-08.doc
2012-08-08
[H7] Outlet (OUT) clogged
Step
DESCRIPTION
1. Fault:
"Outlet clogged"
Cause: Medium cannot flow out of the vacuum chamber (emptying
pump pressure limit = 5 bar)
2.
Check locking features in the return-flow line. Open if blocked.
3.
To reset the failure, press the RESET key
4.
Malfunction reappears after ~ 4 minutes?
->a. Yes
-> proceed to Step 6.
5.
->b. No
-> proceed to Step 7.
6.
Check the pressure relief valve of the evacuation pump for proper
functioning.
7.