![HYDAC FILTER SYSTEMS ContaminationSensor CS 1939 Series Operating And Maintenance Instructions Manual Download Page 32](http://html.mh-extra.com/html/hydac-filter-systems/contaminationsensor-cs-1939-series/contaminationsensor-cs-1939-series_operating-and-maintenance-instructions-manual_2191410032.webp)
Operation
ContaminationSensor CS 1939
en
Page 32 /
48
BeWa CS1939 3978342c V100 en-us 2019-10-08.docx
2019-10-08
Operation
Applying SAE J1939 protocol
The CS 1939 has a CAN 2.0B port with access to the SAE J1939 log.
Whenever the CS is switched on, it sends an "Address Claiming" message to
share its name and address with the other participants. The measurement
values are not transmitted cyclically but rather called up by the PGN 61184
on request.
Parameter definition
PGN
61184
Acronym
PC
Name
CS 1939
Length
14
SPN definition
SPN
Name
P
o
sition
L
e
n
g
th
Typ
e
Reso
lut
ion
Of
fse
t
M
in.
V
a
lu
e
M
a
x.
V
a
lue
Unit
516096
Status
1
8
BitField
516097
ISO 4
9
8
integer
0.1
0.0
8.0
25.0
516098
ISO 6
17
8
integer
0.1
0.0
7.0
24.0
516099
ISO 14 25
8
integer
0.1
0.0
6.0
23.0
516100
ISO 21 33
8
integer
0.1
0.0
5.0
22.0
516101
SAE A 41
8
integer
0.1
0.0
0.0
14.0
516102
SAE B 49
8
integer
0.1
0.0
0.0
14.0
516103
SAE C 57
8
integer
0.1
0.0
0.0
14.0
516104
SAE D 65
8
integer
0.1
0.0
0.0
14.0
516105
Temp
73
16 integer
0.1
-60.0 0.0
185.0 °C
516106
Flow
89
16 integer
0.1
0
30
500
ml/
min
516107
Drive
105 8
integer
0.1
0
0
100
%