![HYDAC FILTER SYSTEMS ContaminationSensor CS 1939 Series Operating And Maintenance Instructions Manual Download Page 26](http://html.mh-extra.com/html/hydac-filter-systems/contaminationsensor-cs-1939-series/contaminationsensor-cs-1939-series_operating-and-maintenance-instructions-manual_2191410026.webp)
Assembly, installation and commissioning
ContaminationSensor CS 1939
en
Page 26 /
48
BeWa CS1939 3978342c V100 en-us 2019-10-08.docx
2019-10-08
Hydraulic installation/assembly
Determine the operating pressure of the hydraulic system and see whether it
is within the permissible flow range for the ContaminationSensor inlet.
NOTICE
Excessive operating pressure
The ContaminationSensor will be destroyed.
►
Note the maximum operating pressure of 350 bar / 5075 psi.
Types of connection of ContaminationSensor
If possible, install the ContaminationSensor so that fluid flows from bottom to
top to avoid air collecting in the sensor. If it is not possible to install it like that,
take other measures to ensure that air cannot collect in the sensor.
Use port A / C as the INLET and B / D as the OUTLET.
Depending on your order, the ContaminationSensor features the following
hydraulic connection types:
Pipe/hose connection:
The ContaminationSensor is
connected to the hydraulic system
via ports A and B using a pipe or
hose.
Flange connection:
The ContaminationSensor is screwed
to a flange, connecting plate,
manifold mount or control block, with
flow through the unit via ports C and
D on the bottom.
Ports A and B exist but are sealed
with a screw plug.
Selecting the measurement location
In order to obtain cleanliness values that are continuous and coherent in real
time, select a suitable measuring point according to the following guidelines: