background image

 

Preface 

 

TAK 

en(us) 

Page 5 / 16 

MoWa TAK 4406591 en-us 2018-08-13.docx 

2018-08-13 

 

Using the documentation 

 

Note that the method described for locating specific information 
does not release you from your responsibility of carefully reading 
these instructions prior to starting the unit up for the first time and 
at regular intervals in the future. 

 

What do I want to know? 

I determine which topic I am looking for. 

 

WHERE can I find the information I’m looking for? 

The documentation has a table of contents at the beginning. There, I select 
the chapter I'm looking for and the corresponding page number. 

 

de

HYDAC Filtertechnik GmbH

BeWa 123456a  de

Seite x

Produkt / K

apitel

200x-xx-xx

 

 

 

 

 

The documentation number with its index enables you to order another copy 
of the operating and maintenance instructions. The index is incremented 
every time the manual is revised or changed. 

 

Chapter description 

 

Page number 

Edition date 

 

Document language 

 

Documentation no. 

with index/ 

file name 

 

Summary of Contents for 3039235

Page 1: ...OLF 5 TAK Tank Connection Kit 2 0 Installation and Maintenance Instructions English translation of original instructions Keep for future reference Document No 4406591 ...

Page 2: ...ter Dipl Kfm Wolfgang Haering Documentation Representative Mr Günter Harge c o HYDAC International GmbH Industriegebiet 66280 Sulzbach Saar Phone 49 6897 509 1511 Fax 49 6897 509 1394 E mail guenter harge hydac com HYDAC FILTER SYSTEMS GMBH All rights reserved No part of this work may be reproduced in any form print photocopy or by other means or processed duplicated or distributed using electroni...

Page 3: ...Preface 4 Technical Support 4 Modifications to the Product 4 Warranty 4 Using the documentation 5 Unpacking the Connection Kit 6 Scope of delivery 6 Product Description 7 Dimensions of the connector threads 8 Hydraulic data 8 Assembling the Kit 9 Suction and return tube 9 Adapter and breather filters 10 Kit disposal 13 Contact Service 13 ...

Page 4: ...ual obligation our liability shall be limited to foreseeable damage Claims due to Product Liability shall remain unaffected Technical Support Contact our technical sales department if you have any questions on our product When contacting us please always include the model code serial no and part no of the product Fax 49 6897 509 9046 E mail filtersystems hydac com Modifications to the Product We w...

Page 5: ...ich topic I am looking for WHERE can I find the information I m looking for The documentation has a table of contents at the beginning There I select the chapter I m looking for and the corresponding page number de HYDAC Filtertechnik GmbH BeWa 123456a de Seite x Produkt Kapitel 200x xx xx The documentation number with its index enables you to order another copy of the operating and maintenance in...

Page 6: ...nation Part number 3039235 1 Manifold block 2 Seal for breather filter 6 Pan head screw M5x120 1 Setscrew M5x8 1 Return tube Ø 38 x 3 1 Suction tube Ø 26 9 x 2 3 length 800 mm with G3 4 thread on one side 200 mm on the free end angled 90 1 Straight screw in union GE 22L G3 4 1 Hose assembly DIN 20066 DN 20 1 SN length 1250 mm 2 Elbow fitting 90 DIN 3942 22L 1 Straight screw in union GE 22L G1 2 2 ...

Page 7: ...ed for rapid retrofitting of bypass flow filter units in hydraulic systems The Kit can be integrated in all systems equipped with a breather filter for which the circuit diagram is executed in accordance with DIN 24557 T2 1 Bypass filtration unit 2 Breather filters 3 Tank breathing 4 Adapter 5 Return tube 6 Suction tube S Suction side R Return flow side ...

Page 8: ...on port S G3 4 Return port R G1 2 Suction tube G3 4 Hydraulic data Flow rate l min Viscosity mm s Suction pressure bar Return pressure bar 5 200 0 3 1 150 0 1 0 7 100 0 06 0 5 46 0 06 0 3 15 90 0 2 1 5 60 0 18 1 2 The tabular values have been determined with the screw connections and flexible lines included in the scope of delivery ...

Page 9: ... in the tank It is imperative that the end of the return tube be positioned below the oil level Observe a maximum distance between the suction and return flow points in order to ensure filtration of the entire tank content Position the suction point as low as possible although not directly on the tank bottom because otherwise sediment could be suctioned up as well 1 Slide the return tube into the ...

Page 10: ...he suction tube Screw the tube into the adapter Adapter and breather filters Note that the circuit diagram of the breather filter must be executed in accordance with DIN 24557 T2 1 Removing the mounted breather filter 2 Remove the existing seal between the breather filter and the tank Clean the sealing faces Mount a new seal ...

Page 11: ...3 docx 2018 08 13 3 Fasten the seal and the adapter on the tank with the M5 x 120 cheese head screws suppled 4 Screw the screwed fittings into the adapter Connect the R and S connections of the adapter and bypass flow filter unit Use the hose lines provided for this purpose ...

Page 12: ...Wa TAK 4406591 en us 2018 08 13 docx 2018 08 13 5 Use a new seal to mount the breather filter on the adapter Use the available fastening screws for this purpose 6 Insert the filter and cover of the breather filter The OLF 5 TAK can now be used ...

Page 13: ...f you have comments or suggestions concerning this manual please contact HYDAC FILTER SYSTEMS GMBH Phone 49 6897 509 1174 Fax 49 6897 509 9046 E mail filtersystems hydac com Regular inspection and maintenance work are indispensable to ensure trouble free operation and a long service life for the unit Our HYDAC ServiCenter offers you these tasks within agreed upon time frames and at fixed prices HY...

Page 14: ......

Page 15: ......

Page 16: ...riegebiet Postfach 1251 66280 Sulzbach Saar 66273 Sulzbach Saar Germany Germany Tel 49 0 6897 509 01 Central Fax 49 0 6897 509 9046 Technical Department Fax 49 0 6897 509 577 Sales Internet www hydac com E Mail filtersystems hydac com ...

Reviews: