2.4
MACHINE ALARMS AND EMERGENCIES
The machine’s controller notifies the operator if any alarm or emergency condition which may occur during operation by
way of acoustic and visual signals. This section lists the message shown on the display.
PRESS RESET
This message is displayed during the initialization phase after pressing the MACHINE START
key.
PRESS RESET
FCTI-FCTA ERROR
This message is displayed when the cutting start position is lower than the previously set head
down position.
Save both the FCTI (head up) and FCTA (head down) positions again.
PRESS RESET
HEAD NOT AT FCTI
This message is displayed if the head is not positioned at the FCTI, position when the cycle is
STARTED.
Return the head to the FCTI (head up) position before resuming the cycle.
PRESS RESET
SELECT SPEED
This message is displayed if the cycle is STARTED without having first selected the cutting
speed.
Return the head to the FCTI (head up) position before resuming the cycle.
PARAMETER
DESCRIPTION
FACTORY SET VALUE
LANGUAGE
Language which will be displayed on the interface
English
MACHINE TYPE
Machine type
S 20 P
MAN & SAD CYCLE
Manual and semi automatic
YES
PEDAL START
Pedal start option
NO
INVERTER
Inverted blade motor drive
YES
BLADE SPEED PROXY Machine equipped with blade speed proximity switch
YES
MINIMAL LUBRIF
Machine equipped with low level lubricant sensor for mist
coolant
NO
RHLS/FHLS OUTS
Head down / head up outputs enabled.
Allows for control board to supply output signal for respective
head position.
NO
STOP BLADE MOTOR
NVR/RHLS/FHLS
Controls when the blade motor is to stop. Values of the
parameter are 0 for when the head is in down limit, for when
the head is in up position and 2 for never.
0
HEAD VISE OPEN
RHLS/FHLS
Controls when to open vise. Values of parameter are 0 for
down limit and for up limit.
0
VISE OPEN/CLOSE
TIME =
Vise open dwell time.
2.0
MAX BLADE MOTOR
I =
Full load amperage of the blade motor. (Depends on voltage of
machine)
8.0
UNIT OF MEASURE
FIPS/MKS
Controls which unit system to display. for imperial, 0 for
metric.
0
BLADE MIN TENS
THRES =
Minimum blade tension required for the machine to start.
600 kg (320 lbs)
LCD BACKLIGHT
DURATION
Time duration of display backlight to stay on min.
0.5
TT =
Total time blade motor run. Software version.
Value depending on run time.
RHLS / FHLS LIMIT
HEAD POS =
Head position -
SEE PROCEDURE
(SETTING the HEAD LINEAR POTENTIOMETER (RHLS/
FHLS LIMIT)
Value depending on head
position.
Summary of Contents for S20P III Series
Page 2: ......
Page 18: ......
Page 38: ......
Page 40: ......
Page 41: ...6 1 FOR MECHANICAL ASSEMBLY DRAWINGS SEE PDF ON ATTACHED CD SECTION 6 MECHANICAL ASSEMBLIES ...
Page 42: ......
Page 46: ...8 2 S20P SERIES III LAYOUT ...
Page 47: ...8 3 S20P SERIES III FOOTPRINT ...
Page 48: ......
Page 50: ......