Version 24DM
Safety and accident prevention
3--7
Emergency devices
In accordance with IEC 204---1Standard:
=
Chapter 5 Section 6 Sub---section 1 ”Emergency stop device”:
«the emergency stop device immediately stops all dangerous and other functions
of the machine.»
=
Chapter 6 Section 2 Sub---section 4 Point 7 ”Protective guards”:
«
the removal of protective guards designed to prevent access to dangerous parts or
zones causes the machine to stop immediately; replacing the guards does not re-
start the functions, which must be reset
»
...emergency devices on DM 8:
1.
Emergency stop:
a no--return mushroom push--button, colour red on yellow
background, is located on the control panel of the machine. To release the
push--button, the actuator must be rotated by 45
˚
. After the emergency situation
has been resolved, the machine must be reset.
2.
Automatic thermal--magnetic cutout switch with thermal--magnetic relay:
the
machine auto switch, located on the control panel, has two protection systems
against voltage drops. In the case of a voltage drop, all electrical components are
disengaged, the machine stops immediately, and automatic restart when the power
supply returns is inhibited. Another function is that of resetting the thermal relay
provided to protect against overcurrents.
3.
Pressure contact for monitoring blade tension:
the machine stops immediately
if the blade breaks or if the tensioner cylinder pressure drops.
4.
Protective guard for blade:
a coded key microswitch is operated if the blade
cover is accidentally or intentionally opened during the machine operating cycle,
immediately shutting down all functions.
1
2
3
4
Summary of Contents for DM8
Page 1: ...CA YEAR OF MANUFACTURE ______________ USE AND MAINTENANCE MANUAL DM 8 ...
Page 2: ......
Page 6: ......
Page 57: ...MEP S p A 6 8 Use and maintenance manual DM 8 DM 8 G 208 60 ...
Page 58: ...Version 24DM Diagrams exploded views and replacement parts 6 9 DM 8 G 208 60 K42 ...
Page 59: ...MEP S p A 6 10 Use and maintenance manual DM 8 DM 8 G 208 60 ...
Page 65: ...MEP S p A 6 16 Use and maintenance manual DM 8 DM 8 G 240 60 ...
Page 66: ...Version 24DM Diagrams exploded views and replacement parts 6 17 DM 8 G 240 60 K42 ...
Page 67: ...MEP S p A 6 18 Use and maintenance manual DM 8 DM 8 G 240 60 ...
Page 73: ...MEP S p A 6 24 Use and maintenance manual DM 8 DM 8 G 575 60 ...
Page 74: ...Version 24DM Diagrams exploded views and replacement parts 6 25 DM 8 G 575 60 K42 ...
Page 75: ...MEP S p A 6 26 Use and maintenance manual DM 8 DM 8 G 575 60 ...
Page 81: ...MEP S p A 6 32 Use and maintenance manual DM 8 DM 8 G 220 Vac ...
Page 82: ...Version 24DM Diagrams exploded views and replacement parts 6 33 DM 8 G 220 Vac K42 ...
Page 83: ...MEP S p A 6 34 Use and maintenance manual DM 8 DM 8 G 220 Vac ...
Page 91: ...MEP S p A 6 42 Use and maintenance manual DM 8 Front flywheel assembly ...
Page 93: ...MEP S p A 6 44 Use and maintenance manual DM 8 Motor flywheel assembly ...
Page 95: ...MEP S p A 6 46 Use and maintenance manual DM 8 Cutting head cover ...
Page 97: ...MEP S p A 6 48 Use and maintenance manual DM 8 Vice assembly ...
Page 99: ...MEP S p A 6 50 Use and maintenance manual DM 8 Base assembly ...
Page 101: ...MEP S p A 6 52 Use and maintenance manual DM 8 Control panel ...
Page 103: ...MEP S p A 6 54 Use and maintenance manual DM 8 Handgrip 3OUT3 ...
Page 105: ...MEP S p A 6 56 Use and maintenance manual DM 8 Reduction gear ...
Page 107: ...MEP S p A 6 58 Use and maintenance manual DM 8 Fixed work table and turntable ...
Page 109: ...MEP S p A 6 60 Use and maintenance manual DM 8 Optional Cut Control System ...
Page 111: ...MEP S p A 6 62 Use and maintenance manual DM 8 Supplementary pneumatic vice ...
Page 113: ......
Page 155: ......
Page 156: ......