1) SMARTFOAM SPECIFICATION
Power Supply:
24 V d.c. 100mA
Response Time:
1, 4, 10 seconds.
Sensitivity:
0 – 9 [0 = dense foam, 9 = light foam]
Nominal Impedance at each Sensitivity Setting (KΩ)
0
1
2
3
4
5
6
7
8
9
0.5
1.75
3.3
5
7.5
10
14
20
27
35
Fouling Immunity:
Sensitivity to fouling <1% of sensitivity to foam with
Hycontrol Sensors.
Output:
'Volt-free' c/o contacts rated at 24 Volts d.c.
at 500 mA max
Connections:
Screw terminals.
Cable:
4 /5 core cable. (e.g. type 16-2-4C, 16x0.2mm)
Head:
Polypropylene, IP66
Dimensions:
20mm Diameter, Length 60, 100 or 150cm
Process entry:
¾” BSPT (R3/4) on standard version
Materials:
Body – 316 Stainless steel, Insulators – PVDF
Design Pressure:
1.5 bars
Design Temperature:
80
o
C