The unit will shut down if an excessive temperature is reached (above 60 degrees). 
 
When you off the water flow the unit will stop heating automatically.   
 
If the unit isn’t in use for a long time switch off the valve and the power. 
 
Note:  Relief Valve Drain  
 
The relief valve (fitted to the water inlet) may discharge water in case of unit 
malfunction, incorrect installation or excess incoming water pressure. An appropriate 
DRAIN or other provision must be fitted to prevent water damage to property.    
  
 

 

TROUBLESHOOTING 
 
PROBLEM 

PROBABLE CAUSE 

REMEDY 

 

NO HOT WATER 

No electrical power supply 

Check the power supply to 

the unit. 

 
 

WATER IS TOO COLD 

A Voltage is too low. 
B Water flow rate is too 
high. 
C Power setting is too low. 

A Check the voltage to the 
unit. 
B Adjust valve to reduce 
water flow rate. 
C Choose a higher power 
setting. 

 
 

WATER IS TOO HOT 

A Water flow is too low. 
B Something is blocking the 
water flow. 
C Power setting is too high. 

A Adjust the valve to 
increase water flow. 
B Clean the inlet filter and 
the spray head. 
C Choose a lower power 
setting. 

HOT WATER 

INADEQUATE 

A Very cold inlet water 

(typically winter) 

A Fit spray head to taps. 

 
 
 
 
  
 