Handing over

Explain the function of the unit to the user, 
in particular, draw his attention to the safety 
instructions. Hand over the installation and 
operating instructions to the user.

Maintenance

 

 

Applicable to all maintenance work: 

 

• Disconnect unit from the mains supply. 

 

• Disconnect cold water pipe from unit. 

 

• Remove unit, drain via the cold and hot 
water connection pieces and place on a 
table.
 

To remove the casing 

(Fig. 11):

 Pull off thermostat knob, remove screws.

 

On the under side, lower the locking 
screws towards the inside by rotating 
them counterclockwise or clockwise.

 

Swing open casing and remove. Untighten 
the plastic band of the HF10L.

The unit is now accessible for all maintenance 
work.

Exchange cable

If the electric cable has to be removed, the 
plastic thread which holds the form plate must 
not be removed!

Sensor positioning 

HF05L

The thermostat sensor and the safety thermal 
cut-out sensor in the HF05L are located in 
different capillary tubes. The thermostat sen-
sor should be positioned in accordance with 
Figure 12.

HF10L

The thermostat sensor and the safety thermal 
cut-out sensor in the HF10L are located 
within the same capillary tube and should be 
positioned in accordance with Figure 13.

Descaling

Remove heating flange, remove coarse calci-
um with a piece of wood, immerse heating 
element up to the flange plate into decalcitant.

Faults to be cleared by an 
approved professional

 

If the thermal cut-out operates by 
using the water heater normally, the 

reason for the fault must rectified and the 
thermostat must be replaced.

Environment and recycling

Recycling of obsolete appliances

Appliances with this label must not be 

disposed off with the general waste. 

They must be collected separately and 

disposed off according to local regulations.

5135.01

4753.02

4754.01

Fig. 11

plastic band
HF10L only

8722.01

8721.01

200 mm

260 mm

130 mm

HF10L

Fig. 12

HF05L

Fig. 13/Afb. 13

Summary of Contents for Handyflow HF05L

Page 1: ...serviced by approved service technicians in accordance with these instructions Fig 1 HF05L Hyco Handyflow 5L HF10L Hyco Handyflow 10L Point of Use Water Heater Operating and installation instructions...

Page 2: ...otherwise To avoid risk of accidental resetting of the protective temperature restrictor in the event of a fault the unit must not be con nected via a timer switch If you experience kettling noises o...

Page 3: ...eight 3 0 kg 5 1 kg Heating power see unit rating plate Voltage 230V Flow rate max 5 l min 10 l min Protection to EN 60529 IP 24 D Connection line approx 700 mm Temperature setting range fully adjust...

Page 4: ...heater must be installed vertical ly with the inlet and outlet connections at the bottom of the unit Fig 5 and 6 The inlet tap should be fitted to the right hand connection cold water inlet Fig 6 The...

Page 5: ...ure can reduce the risk of scalding save energy reduce scaling The temperature can be limited to 38 C 45 C 55 C and 65 C Fig 10 key 1 Thermostat control knob 2 Factory set position 85 C 3 Limiting pos...

Page 6: ...he thermostat sensor and the safety thermal cut out sensor in the HF05L are located in different capillary tubes The thermostat sen sor should be positioned in accordance with Figure 12 HF10L The ther...

Page 7: ......

Page 8: ...8 1 8238 HD Subject to errors and technical changes HYCO Manufacturing Ltd Units 1 2 Calder Works Methley Road Castleford West Yorkshire WF10 1NX Tel 0 1 9 7 7 5 1 7 5 5 5 Tel 0 1 9 7 7 5 1 7 6 6 6 Ma...

Reviews: