Electrical connection

The water heater must be installed in accor-
dance with I.E.E Regulations.

Wiring diagram

 (Fig. 8)

1

  Earth cable connector

2

  Signal lamp

3

  Thermostat

4

  Safety thermal cut-out with reset function

5

  Heating element

*  For voltage and current information,    
  please refer to the rating label.
Any excess cable can be stored in the com-
partment in the rear of the unit (Fig. 9).
The unit should be installed with a fixed cable  
connection (spur point). An isolator with at 
least 3 mm separation on all poles must be 
used in the AC mains circuit.

Temperature limiting

 (Fig. 10)

Limiting the temperature can:
 

  reduce the risk of scalding,

 

  save energy

 

  reduce scaling

The temperature can be limited to 38 °C, 
45 °C, 55 °C and 65 °C.
Fig. 10 key:

1

  Thermostat control knob

2

  Factory set position - 85 °C 

3

  Limiting possibilities.

 

Warning! 
This appliance must be earthed.

Commissioning

1.  Open hot tap fully until flows free of bubb-

le.

2.  Switch on and select temperature.

 

Risk of running dry! 

A thermal cut-out is fitted within 

the appliance. If this operates for safety 
reasons it can be reset by simply turning 
off the electrical supply to the water hea-
ter. When the supply is switched on again 
the thermal cut-out will have reset. If the 
problem continues, fault finding should be 
carried out by a qualified installer.

4752.01

Fig. 9

3

1

2

4745.03

Fig. 10

38

Fig. 8

8731.01

L N

L N PE

1/N/PE ~ 230V

8731.01

1/N/PE ~ *

1

2

4

3

5

Summary of Contents for Handyflow HF05L

Page 1: ...serviced by approved service technicians in accordance with these instructions Fig 1 HF05L Hyco Handyflow 5L HF10L Hyco Handyflow 10L Point of Use Water Heater Operating and installation instructions...

Page 2: ...otherwise To avoid risk of accidental resetting of the protective temperature restrictor in the event of a fault the unit must not be con nected via a timer switch If you experience kettling noises o...

Page 3: ...eight 3 0 kg 5 1 kg Heating power see unit rating plate Voltage 230V Flow rate max 5 l min 10 l min Protection to EN 60529 IP 24 D Connection line approx 700 mm Temperature setting range fully adjust...

Page 4: ...heater must be installed vertical ly with the inlet and outlet connections at the bottom of the unit Fig 5 and 6 The inlet tap should be fitted to the right hand connection cold water inlet Fig 6 The...

Page 5: ...ure can reduce the risk of scalding save energy reduce scaling The temperature can be limited to 38 C 45 C 55 C and 65 C Fig 10 key 1 Thermostat control knob 2 Factory set position 85 C 3 Limiting pos...

Page 6: ...he thermostat sensor and the safety thermal cut out sensor in the HF05L are located in different capillary tubes The thermostat sen sor should be positioned in accordance with Figure 12 HF10L The ther...

Page 7: ......

Page 8: ...8 1 8238 HD Subject to errors and technical changes HYCO Manufacturing Ltd Units 1 2 Calder Works Methley Road Castleford West Yorkshire WF10 1NX Tel 0 1 9 7 7 5 1 7 5 5 5 Tel 0 1 9 7 7 5 1 7 6 6 6 Ma...

Reviews: