Diagram 1

• 

The unit can be installed with the inlet and outlet at the top or at the bottom. Ensure 

the bracket orientation corresponds with the unit. When installed with the inlet and 

outlet at the bottom of the heater the electronic temperature display will rotate 

automatically. 

• 

Mark and drill two holes using the bracket as a template. Use the supplied wall plugs 

and screws to attach the bracket to the wall (see Diagram 1). 

• 

Refit the unit to the bracket to complete mounting.

Cable defaults out of the right hand side when viewed from the front and installed with the inlet/ 

outlet at the top of the unit. Supplied pre knocked out but can be changed if desired. 

Summary of Contents for Ara IN30T

Page 1: ...Product Instruction Manual Ara Instantaneous Inline Water Heater IN30T v20 8 1...

Page 2: ...e power required to deliver the chosen temperature Not suitable for use with thermostatic mixing valves or taps or to supply a mixer tap The appliance must only be connected to a single phase supply I...

Page 3: ...or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Childre...

Page 4: ...the risk of freezing cannot be managed The heater is not suitable for use with thermostatic mixing valves or taps or to supply a mixer tap Removing and Mounting the Bracket Use a flat headed screwdriv...

Page 5: ...onic temperature display will rotate automatically Mark and drill two holes using the bracket as a template Use the supplied wall plugs and screws to attach the bracket to the wall see Diagram 1 Refit...

Page 6: ...ide of the heater blue collar It is recommended a service valve not supplied is fitted on the incoming supply to facilitate any future maintenance Make a connection from the outlet side of the heater...

Page 7: ...nd water supply before electrical installation Ensure all wiring provisions meet the specifications of the heater as stated on the rating label and Specification section of this manual Make connection...

Page 8: ...eating when it detects a flow of water through it On first installation the heater requires an initial 12 seconds approx of continuous water flow through the unit to start heating When the water flow...

Page 9: ...y result in incoming temperatures below 10 C whereas summer water temperatures can be upwards of 15 C It is imperative this is taken into account For example the heater could deliver 42 C water in the...

Page 10: ...setting Turn anticlockwise for maximum water flow Turn clockwise to reduce the water flow Adjusting Water Flow Rate Diagram 4 A flow restrictor is supplied and must be fitted to the outlet tap attach...

Page 11: ...connect the power before commencing any cleaning or maintenance Never open the cover of the heater without first isolating the mains power supply If the flow rate drops on the heater check the spray h...

Page 12: ...13A Overheat protection temperature 85 C Min operating flow rate 1 2 l min Min operating pressure 0 05 MPa 0 5 bar Max rated pressure 0 8 MPa 8 bar Required water resistivity 15 C 1300 cm Max incoming...

Page 13: ...t the heater does not display any temperature when water is flowing Flow rate is too low Ensure a minimum flow of 1 2 l min The control lights illuminate but the heater does not display any temperatur...

Page 14: ...t you should first contact our service department on 01924 225 200 before taking any further action Experience has shown that issues can often be resolved without the need to return or uninstall the p...