background image

Contents

1.           Important safety points

2.           Installation 

2.1.        Wall mounting

2.2        Electrical

3.           Operation - Non-timer models

4.           Operation – 7-day timer models

4.1        How to set the date and time on your heater

4.2        Setting the target temperatures

4.3        Selecting a pre-loaded schedule

4.4        Programming your own customised schedule

5.           Advanced features (7-day timer models)

5.1        Copy and paste programming

5.2        Activating the child lock

5.3        Centigrade / Fahrenheit display

5.4        Delayed start and shut down mode

6.           Maintenance

7.           Specifications

8.           Guarantee and service policy

2

Summary of Contents for Accona AN1500

Page 1: ...Product Instruction Manual Accona AN500T AN1000 AN1000T AN1500 AN1500T AN2000 AN2000T Panel heater Version 3 2 Jan 2015 v16 5 5 ...

Page 2: ... time on your heater 4 2 Setting the target temperatures 4 3 Selecting a pre loaded schedule 4 4 Programming your own customised schedule 5 Advanced features 7 day timer models 5 1 Copy and paste programming 5 2 Activating the child lock 5 3 Centigrade Fahrenheit display 5 4 Delayed start and shut down mode 6 Maintenance 7 Specifications 8 Guarantee and service policy 2 ...

Page 3: ...er or an authorised service agent for replacement Do not carry the appliance by the power cord Do not let the power cord hang over the appliance The heater must not be located immediately below or above an electrical socket outlet This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge i...

Page 4: ...bath or shower 2 Installation Wall Mounting The heater must not be located immediately below or above an electrical socket outlet Only use the mounting bracket supplied and do not modify the bracket Fixed heaters likely to be used in bathrooms are to be installed so that switches and other controls cannot be touched by a person in the bath or shower Step 1 Choose a suitable location for the mounti...

Page 5: ...mark the outer holes through the bracket onto the surface of the mounting wall Drill and fit wall plugs and then fix the bracket to the mounting surface Step 3 Offer up the heater to the bracket and attach as per figure 2 Fasten the clips and verify heater is securely fixed to the wall 5 ...

Page 6: ...ed to the fixed wiring of the property then installation must include a double pole isolating switch with a break contact distance of at least 3mm The power cord should be connected following the colour coding below Brown L Blue N Green Yellow E 3 Operation non timer models AN1000 AN1500 AN2000 1 Control Unit 4 Temperature Control Knob 2 Air Outlet 5 Power Indicator 3 Air Inlet 6 Switch ON OFF O T...

Page 7: ...mperature Indicator 15 Timer On Off Button 7 Temperature Setting Button 16 On Off Indicator 8 Program Select Button 17 LCD Display 9 User Program Setting Button 4 1 How to set the date and time on your heater The below example illustrates how to set the clock to Thursday 3 03PM Step 1 Press the clock icon once this will cause the day of the week to start flashing Step 2 Use the up down icons to cy...

Page 8: ...clock to finalise the time 4 2 Setting the target temperatures The thermostat settings can only be set whilst the unit is turned on not standby Unlike many panel heaters the Accona timer range utilises two temperature ranges The first is the temperature the heater will maintain during the Peak setting and the second is the Off peak setting Peak When you want a comfortable temperature whilst occupy...

Page 9: ... icon to store the Peak temperature and also move onto the Off peak setting Off peak is indicated by the symbol which will flash when selected Step 4 As with step 2 it is possible to alter the target temperature for the Off peak mode by simply pressing the up down symbols the desired number of times In this example the down icon has been pressed three times to change the target temperature from 17...

Page 10: ...24 represent time on a 24 hour clock and equates to midnight 8 00am 4 00pm and midnight respectively 2 The symbol means the heater operates in OFF PEAK MODE during the given time 3 The i symbol means the heater operates in PEAK MODE during the given time 4 CF means FROST PROTECTION MODE the unit will heat only to avoid frost and protect it when the room temperature is very low The temperature cann...

Page 11: ...ss the P icon to store and run this setting The display will now show the selected schedule 4 4 Programming your own customised schedule Along with a number of pre set schedules see table in previous section there is also one schedule that can be used to create your own custom timer settings This schedule is represented by the initials UP user programmed Step 1 First select the UP mode from the pr...

Page 12: ...tures 7 day timer models 5 1 Copy and paste programming To make creating a UP custom schedule slightly easier you may wish to copy and paste a full day s programme onto another day For instance you have set Monday s programme and you wish to replicate this for the remaining week days This can be achieved by copying and pasting Monday s settings on to the remaining days this will negate the need to...

Page 13: ... 1 of this section to repeat for other days 5 2 Activating the child lock The timer unit can be locked on your heater in order to prevent settings being altered Step 1 Press the P icon once Step 2 Push and hold the timer and programme icons for 2 3 seconds Step 3 When the timer is successfully locked a key icon will be displayed to confirm this Step 4 To unlock the timer simply repeat the steps fo...

Page 14: ...ss the alarm icon again to exit timer mode and save the selection The heater will now start up automatically in ten hours time It is possible to programme the heater to switch off in a specified number of hours in the future Step 1 The heater must be On not in standby to utilise this feature Press the alarm clock icon and a symbol for a clock will be displayed Step 2 Use the up down icon to enter ...

Page 15: ...a soft dry cloth Never use chemical or abrasive cleaners 7 Specifications Model AN500T AN1000 AN1000T AN1500 AN1500T AN2000 AN2000T Voltage 230v 230V 230V 230V 230V 230V 230V 50Hz 50Hz 50Hz 50Hz 50Hz 50Hz 50Hz Power 0 5kW 1 0kW 1 0kW 1 5kW 1 5kW 2 0kW 2 0kW Weight 4 4kg 5 1kg 5 1kg 6 2kg 6 2kg 7 4kg 7 4kg Dimensions 440 x 445 440 x 580 440 x 580 440 x 700 440 x 700 440 x 855 440 x 855 H x W x D x ...

Page 16: ...onic equipment separately enables its components to be recovered and recycled to obtain significant savings in energy and resources In order to underline the duty to dispose of this equipment separately the product is marked with a crossed out dustbin 8 Guarantee and service policy This product is guaranteed against faulty materials and manufacture for a period of one year from the date of purchas...