background image

2A

1. Safety Instructions

 

WARNING

Please keep this User Manual for future consultation. If you sell the fixture to another
user, be sure that they also receive this instruction booklet.

Unpack and check carefully that there is no transportation damage before using the
fixture.

Before operating, ensure that the voltage and frequency of power supply match the
power requirements of the fixture.

It’s important to ground the yellow/green conductor to earth in order to avoid electric
shock.

Disconnect main power before servicing and maintenance.

Use safety chain when fixing this fixture. Don’t handle the fixture by taking its head only,
but always by taking its base.

Maximum ambient temperature is Ta : 40

. Don’t operate it where the temperature is

higher than this.

In the event of a serious operating problem, stop using the fixture immediately. Never
try to repair the fixture by yourself. Repairs carried out by unskilled people can lead to
damage or malfunction. Please contact the nearest authorized technical assistance
center. Always use the same type of spare parts.

Do not connect the device to any dimmer pack.

Do not touch any wire during operation as there might be a hazard of electric shock.

To prevent or reduce the risk of electrical shock or fire, do not expose the fixture to rain
or moisture.

The housing must be replaced if it is visibly damaged.

Do not look directly at the LED light beam while the fixture is on.

Caution

There are no user serviceable parts inside the fixture. Do not open the housing or attempt
any repairs yourself. In the unlikely situation that your unit may require service, please
contact your nearest dealer.

Please read the instructions carefully which include important

information about the installation, operation and maintenance.

Summary of Contents for HSS COB-C

Page 1: ...User Manual Please read the instructions carefully before use ...

Page 2: ...OF CONTENTS 1 Safety Instructions 2 Technical Specifications 3 Installation 4 How to set up the unit 5 How to control the fixture 6 DMX512 Configuration 7 DMX512 Connections 8 Troubleshooting 9 Fixture Cleaning ...

Page 3: ...rious operating problem stop using the fixture immediately Never try to repair the fixture by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type of spare parts Do not connect the device to any dimmer pack Do not touch any wire during operation as there might be a hazard of ele...

Page 4: ... 75kg 3 Installation The unit should be mounted via its screw holes on the bracket Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit s weight Always use a safety cable that can hold 12 times of the weight of the unit when i...

Page 5: ...for the next unit DMX input For DMX512 link use 3 pin XLR plug cable to input DMX signal DMX output For DMX512 link use 3 pin XLR plug cable to link the next unit Note 1 In ten seconds if no button was pressed the LED display will turn off Press any button to turn on the LED display again 2 Whenever any button has been pressed the program will save all parameter after 2 seconds 3 No matter the pro...

Page 6: ...address remotely by the universal DMX controller First you need to program two scenes into a chase then link the fixtures to the universal DMX controller When you run the chase all the fixtures of the chain will be set to the series DMX address automatically The fixture uses four channels Please refer to the following diagram to set the address for the first four units B Master Slave operation The...

Page 7: ...st be connected to the last fixture DMX output cable daisy chain Any fixture can act as a Master or as a Slave Channels mode Unit1 Address Unit2 Address Unit3 Address Unit4 Address CH5 1 6 11 16 6 DMX512 Configuration Channel Value Function CH1 0 5 Dimming mode 6 180 Auto Run Macro 1 Macro7 181 205 sound mode 1 206 230 sound mode 2 231 255 sound mode 3 CH2 0 255 Master dimming CH1 6 0 255 Auto Run...

Page 8: ... 3 The DMX output and input connectors are pass through to maintain the DMX circuit when one of the units power is disconnected 4 At the last fixture the DMX cable has to be terminated with a terminator to reduce signal errors Solder a 120 ohm 1 4W resistor between pin 2 DMX and pin 3 DMX into a 3 pin XLR plug and plug it in the DMX output of the last fixture 5 Each lighting fixture needs to have ...

Page 9: ...n near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C Some fixtures don t respond to the easy controller 1 You may have a break in the DMX cabling Check the LED for the response of the master slave mode signal 2 Wrong DMX address in the fixture Set the proper address D No response to the sound 1 Make sure the fixture does not receive DMX si...

Reviews: