![Hwasung HMK-072 User Manual Download Page 28](http://html1.mh-extra.com/html/hwasung/hmk-072/hmk-072_user-manual_2190556028.webp)
Title
Rev.
Page
HMK-072
Ver1.0
P.27
CR
[Function]
Print and carriage return
[Code]
ASCII
CR
Hex
0Dh
Decimal
13
[Range]
-
[Description]
Equal to LF.
LF
[Function]
Print and line feed
[Code]
ASCII
LF
Hex
0Ah
Decimal
10
[Range]
-
[Description]
①STANDARD MODE:
After printing the data and go to return accordingly to fixed data.
②PAGE MODE:
Only the fixed data can be conducted, according to the fixed data.
[Caution]
The LF is ignored behind of CR
CAN
[Function]
Cancel print data in page mode
[Code]
ASCII
CAN
Hex
18h
Decimal
24
[Range]
-
[Description]
The print data will be deleted in print area
HT
[Function]
Horizontal tab
[Code]
ASCII
HT
Hex
09h
Decimal
9
[Range]
-
[Description]
Moves the print position to the next tab position
[Caution]
Horizontal tab positions are to set in ESC+’D’+n.
Summary of Contents for HMK-072