![Hwasung HMC-060 Technical Manual Download Page 34](http://html1.mh-extra.com/html/hwasung/hmc-060/hmc-060_technical-manual_2190553034.webp)
Title
Rev.
Page
HMC-060, HMK-060 Release 2
Ver2.0
P.33
FS+’
.’
[Name]
Cancel Korean mode (2Bytes mode)
[Format]
ASCII
FS
.
Hex
1C
2Eh
Decimal
28
46
[Descript]
Cancel Korean mode (2Bytes mode)
[Caution] In case of cancel 2 bytes mode in extended graphic mode
Appointment is not required due to auto detection in Korean mode
(Ref.SUB+’x’+n command)
FS+’-’+n
[Name]
Set the underline of Korean
[Format]
ASCII
FS
-
n
Hex
1C
2Dh
n
Decimal
28
45
n
[Range] 0≤n≤2
[Initial Value] n=0
[Descript]
Set the underline of Korean
n
Function
0
Cancel the underline of Korean
1
Set the thickness of underline in 0.125mm
2
Set the thickness of underline in 0.25mm
3
Set the thickness of underline in 0.375mm
4
Set the thickness of underline in 0.5mm
5
Set the thickness of underline in 0.625mm
6
Set the thickness of underline in 0.75mm
7
Set the thickness of underline in 0.875mm
FS+’S’+n1+n2
[Name]
Set the space between Korean characters
[Format]
ASCII
FS
S
n1
n2
Hex
1C
53h
n1
n2
Decimal
28
83
n1
n2
[Range]
0≤n1≤255, 0≤n2≤255
[Initial Value]
n=0
[Descript]
Set the space between Korean characters
Set the left space in n1×0.125mm
Set the right space in n2×0.125mm