HWAM I 30/65 User Manual Download Page 10

Page 10 of 20 pages

m

ountIng

 

and

 

connectIon

 

The HWAM I 30/65 consists of a moveable, external brickwork casing, as well as an insert that is pushed 
into place and connected once the brickwork casing has been assembled.

The HWAM I 30/65 can be connected in two ways:

1. Mounting and connecting in an existing fireplace.
2. New construction around the insert, possibly including heat ducts to other rooms.

1. Mounting and connecting in an existing fireplace (Drawing A1-A3)

Before mounting the insert in a brick-built fireplace, the regulating damper in the existing chimney must 
be removed and the smoke neck, if any, should be widened so that the fire tube from the insert can be 
connected directly to the chimney. Any bricks positioned on edge at the bottom of the fireplace should 
also be removed.

In advance, decide with a specialist or the chimney sweep where a soot door 

(1)

 should be placed, so 

that the fire tube can be cleaned from above while the door of the insert remains closed.

Mounting the smoke pipe (Drawing A1)

First mount the joining flange 

(2)

 with a suitable length of fire tubing or flexible tubing 

(3)

. Push the 

inner pipe into the connector. The inner pipe must be turned so that the handle goes as far as possible 
into the connector.

Trim approximately 3 fireproof batts of 50 mm each 

(4)

 so that they fit tightly into the chimney space 

and cut a hole in the centre to fit tightly around the tube.

Place the fire tube in the chimney so that the joining flange corresponds to the given measurements. 
a. Distance from front edge of the brick hole, if the insert must be flush with the brickwork.
b. Height over the bottom of the insert.

Now push the three batts up around the fire tube and press them up into the chimney thereby achieving 
a compact and tight-fitting seal.

Installing the outer casing (Drawing A2)

If you would like to mount hoses in order to distribute a portion of the convection heat to other rooms, 
push the two plates on each side of the smoke outlet hole on the casing outwards 

(see drawing H)

.

Push the outer casing 

(6)

 into place at the bottom of the fireplace. Carefully ensure that the outer casing 

is level and that its front edge is flush with the brickwork. The three adjustment screws in the bottom of 
the casing can be used for fine adjustment so that the casing is completely level 

(drawing F). 

Screw the 

connector to the building-in cassette with the help of the self-tapping screws supplied.

If the gap between the fireplace aperture and the outer casing is to be closed with brickwork, there must 
be a minimum distance of 5 mm around the outer casing The brickwork above the outer casing must 
therefore be self-supporting. Attach the casing to the masonry with 1-3 screws in the base.

Mounting the insert (Drawing A3) 

Remove the smoke shelf 

(7)

 from the insert. Remove the smoke deflector plate 

(8)

 from the insert.  

Attach an Ø6 mm seal to the bottom the smoke outlet bushing. Then push the insert into place in the 

Summary of Contents for I 30/65

Page 1: ...User s manual EN 01 11 2020 97 9642 www hwam com I30 65 AUTOPILOT...

Page 2: ...Drawings 4 6 Installation manual 8 Mounting and connection 10 Firing manual wood 12 Firing in general 14 Cleaning 15 Maintenance 16 Operational problems 18 Declaration of Performance 18 Product inform...

Page 3: ...Page 3 of 20 pages 1 1 1 A1 A2 A3 7 8 5 6 5 4 3 2 1 b 40 4 cm 2 a 39 1 cm...

Page 4: ...Page 4 of 20 pages B D C 2 1 3 5 4 3 6...

Page 5: ...Page 5 of 20 pages E F G 1 1 1 2 2 H...

Page 6: ...Page 6 of 20 pages...

Page 7: ...he air control lever A window that can be opened or an adjustable air valve will be sufficient It must not be possible to block the adjustable air valve grate In newly built airtight dwellings we reco...

Page 8: ...N 13240 measurement point If measured just above the smoke flue socket the chimney draught must be 18 20 Pa The chimney must have a minimum clearing of 150 mm The chimney must be provided with an eas...

Page 9: ...duct and the smoke chamber above the baffle plate must be cleaned together with the chimney If the chimney is too tall to be cleaned from above it must be equipped with a soot door In case of a chimne...

Page 10: ...ntre to fit tightly around the tube Place the fire tube in the chimney so that the joining flange corresponds to the given measurements a Distance from front edge of the brick hole if the insert must...

Page 11: ...ng The frame of the outer casing has a width of 25 mm though only 20 mm at the top Any brick work stretching across the outer casing must be self supporting Remember the screws between the outer casin...

Page 12: ...ce and pine are more easy to light up They burn faster and give off fewer ambers You may therefore take advantage of the light types of wood for lighting and use the heavier types of wood to ensure a...

Page 13: ...sation forms on the glass for a maximum of 5 min Close the door When the kindling is burning well push the output regulating rod into middle position If the fire goes out this has been done too early...

Page 14: ...sary to burn more wood How to achieve the best combustion Use clean and dry wood Wet wood results in inefficient combustion plenty of smoke and soot Furthermore the heat will dry the wood not heat up...

Page 15: ...in halfway up pull out the top guide latches on the sides ease the glass pane into place and lead the guide latches back into place over the screws The inside of the glass pane is best cleaned with da...

Page 16: ...with copper grease if necessary drawing B 1 Check the spring in the Autopilot unit and replace if necessary Checking gaskets Replace gaskets if they are not intact or are no longer soft Inspection of...

Page 17: ...e door slides too easily the spring has loosened The spring can be loosened or tightened as follows Remove the insert from the outer casing Make sure the door of the combustion chamber 3 is closed Att...

Page 18: ...open the door when there are still flames on the wood Uncontrollable combustion Faulty seal in door or ash pan Fit new seal If there is an excessive chimney draft it may be necessary to set the air co...

Page 19: ...items in a way that is as sustainable as possible and that is in line with the current environmental protection reprocessing recycling and disposal technology Useful efficiency at nominal heat output...

Page 20: ...www hwam com...