All dimensions in connection with corner installation are only recommendations. Contact your chimney
sweep for a clarification.
Remember to pay attention to any regulations concerning the required distance between
the wall and smoke pipe.
Please be aware that not all glass parts are heat-resistant. For this reason, a glass wall should sometimes
be treated as a flammable wall, in which case we ask you to contact your local chimney sweep or glass
producer to hear at what distance the stove should be kept from glass.
Requirements for chimney and smoke pipe
The chimney must be of a sufficient height to enable an adequate draft and to prevent smoke problems.
The stove requires a draft of at least 12 Pa.
The chimney must have a minimum opening equivalent to Ø 150 mm. The chimney opening should
always be at least the size of the outlet socket of the stove. The chimney must have an easily accessible
soot door.
Smoke pipe and chimney must always be suitable for a stove connection. Ask your HWAM dealer for
more information.
Connection to chimney
All the stoves have both rear and top smoke outlet that can be connected to an approved steel chimney on
top or directly out at the rear to a chimney.
Make sure that the chimney is tight and that no false draft is caused around neither the cover plate, in
connection with a covered smoke outlet, nor the cleanout door and pipe connections. Please note that
bent and/or horizontal smoke pipes will reduce the effect of the chimney draft.
Vertical cross-section of smoke flue (Drawing B and C)
B: Top smoke outlet
C: Rear smoke outlet
• Steel chimney (9).
• Flue gas elbow (10).
• Brick-built jamb of flue (11).
• Built-in pipe sleeve (12). Fits smoke flue.
• Wall rosette (13). Covers disruption to wall around pipe sleeve.
• Joint (14). Sealed with gasket.
• Smoke outlets (15) of the HWAM stove.
• Smoke flue regulating damper (16).
• Soot door (17).
Fitting the loose parts
Before the stove is installed, you must ensure that all loose parts are fitted correctly.
Vertical cross-section of the stoves (Drawing B):
• The smoke shelf (5). To be placed on top of the steel rail and on the holders in the sides.
• Two-piece smoke defector plate (6). Each half is hung on the hooks located beneath the top plate. The two
halves join in the holders behind the air pipe. Once the stove has been installed, twist the protection off
the two hooks by using pliers or a screwdriver.
• Cover plate (7). Should always cover the grate.
• Removable rear plate (2), covering Autopilot controls. This must always be mounted if the stove is
placed next to a combustible wall.
• Loose heat shield (8) under the ash pan. This can be used as a lid when the ash pan is removed for
emptying.
Summary of Contents for Autopilot IHS 7100
Page 2: ...2...
Page 4: ...4 B C A 3 1 1 4 45 4 3 2 1 9 11 10 17 16 14 12 13 5 6 7 8 2 15 14 13 12 11 5...
Page 5: ...5 F 3 1 2 4 5 D E 1...
Page 6: ...6 G 3 0 4 4 4 4 4 2 2 3 1 3 1...
Page 7: ...7 H...
Page 35: ...35...
Page 45: ...45...
Page 46: ...46...
Page 47: ...47...
Page 48: ......
Page 49: ......
Page 50: ......
Page 51: ......