15
Make sure that the chimney is tight and that no false draft is caused around neither the cover plate, in
connection with a covered smoke outlet, nor the cleanout door and pipe connections. Please note that
bent and/or horizontal smoke pipes will reduce the effect of the chimney draft.
Vertical cross-section of smoke flue (Drawing C)
C1: Top smoke outlet
C2: Rear smoke outlet
1. Steel chimney.
2. Flue gas elbow. Fits into smoke flue socket.
3. Brick-built jamb of flue.
4. Built-in pipe sleeve. Fits smoke flue.
5. Wall rosette. Covers disruption to wall around pipe sleeve.
6. Joint. Sealed with packing material.
7. Smoke outlets of the HWAM stove.
8. Cover plate in the external rear plate – break off if a rear outlet is required.
9. Cover screwed in position: secure it to the top plate with screws if a rear outlet is required.
10. Smoke bushing: to be screwed to the back of the stove if a rear outlet is required.
11. Adjusting damper in smoke pipe.
12. Cleaning hatch.
13. Smoke pipe to rear outlet.
14. Loose cast iron cover: to be placed on the top plate when there is a rear outlet.
Chimney
The chimney is the “engine” of the stove and it is crucial for the functioning of the woodburning stove.
The chimney draft provides a partial vacuum in the stove. The partial vacuum removes the smoke from
the stove, sucks air through the damper to the so-called pane flush mechanism, which keeps the window
pane soot free, and sucks air into the combustion via the HWAM Autopilot IHS
TM
.
The chimney draft is created by the differences in temperature inside and outside the chimney. The higher
the temperature within the chimney, the greater the draft (a brick chimney takes longer to warm up than
a steel chimney). On days where the weather and wind conditions create insufficient draught inside the
chimney, it is even more important to warm up the chimney as quickly as possible. The trick is to quickly
get some flames going. Split the wood into extra fine pieces, use an extra firelighter, etc.
If the stove has not been used for a longer period, it is important to check that the chimney pipe is not
blocked. It is possible to connect several devices to the same chimney. However, it is important to first
check the applicable rules.
Even a good chimney can function badly if it is not used correctly. Similarly, a bad chimney may function
well if used correctly.
Chimney sweeping
To prevent the risk of chimney fires, the chimney must be cleaned every year. The flue duct and the smoke
chamber above the baffle plate must be cleaned together with the chimney. If the chimney is too tall to
be cleaned from above, it must be equipped with a soot door.
In case of a chimney fire and overheating, the HWAM Autopilot IHS
TM
will enter a security mode and
automatically adjust all dampers, effectively quenching the fire. Do not open the stove door, since that
might cause the fire to rekindle. Contact the fire brigade. After a fire, the stove should be checked by a
chimney sweep before use.
Summary of Contents for 4510
Page 1: ...User s Manual EN 05 09 2017 97 9688 www hwam com 4530 4550 4560 4540 4520 4510 ...
Page 2: ......
Page 4: ...4 A1 1 2 3 4 3 4 1 A2 B A ...
Page 5: ...5 C 1 2 3 5 4 6 6 7 8 9 11 12 10 C1 C2 4 6 6 7 14 13 3 9 10 E ...
Page 6: ...6 F ...
Page 7: ...7 F ...
Page 8: ...8 F ...
Page 22: ...22 ...
Page 23: ...23 ...
Page 24: ...www hwam com ...