Blackened glass
• The wood is too damp. Only use wood stored for at least 12 months under cover and with a
moisture level not exceeding 20% RH.
• Faulty seal in door. Fit new seal.
Smoke in the room when opening door
• The grate in the chimney may be closed. Open the grate.
• Insufficient chimney draft. See section on chimney or contact chimney sweep.
• Soot door leaking or dislodged. Replace or refit.
• Never open the door when there are still flames on the wood.
Uncontrollable combustion
• Faulty seal in door or ash pan. Fit new seal.
• If there is an excessive chimney draft, it may be necessary to close the regulator. Close the regulator
when the stove is not in use.
• If the steel plates in the combustion chamber develop scales or become deformed, this is due to
excessive heat. Stop using the stove and contact the dealer.
At interruptions that you cannot yourself rectify, you should contact the dealer.
d
eclaratIon
oF
P
erFormance
The DoP can be downloaded from our website via the following links:
HWAM 2610:
www.hwam.com/dop/2610
HWAM 2620:
www.hwam.com/dop/2620
HWAM 2630:
www.hwam.com/dop/2630
HWAM 2640:
www.hwam.com/dop/2640
Summary of Contents for 2610
Page 2: ...2 ...
Page 4: ...4 B C A 3 1 1 4 45 4 3 2 1 11 12 14 14 15 9 11 10 17 14 12 13 1 4 6 5 15 7 8 16 ...
Page 5: ...5 E F D 1 1 2 3 ...
Page 6: ...6 G ...
Page 7: ...7 H ...
Page 42: ...42 ...
Page 43: ...43 ...
Page 44: ...44 ...
Page 45: ...45 ...
Page 46: ......
Page 47: ......